3. Sidewalls/Surrounds
Adjacent combustible side walls must be located a minimum of 12 in. from the fireplace opening. See Figure 6. If
you are using a decorative surround constructed of combustible material, it must be located within the shaded area
defined in Figure 6. Short stub walls are also acceptable if they are contained within the shaded area.
When planning your fireplace location, the chimney construction and necessary clearances must be considered. The
fireplace system and chimney components have been tested to provide flexibility in construction. The following figures
are the minimum distances from the base of the fireplace.
12
Cat #
A
E/EC36
36 in. - 914 mm
E/EC39
39 in. - 991 mm
E/EC42
42 in. - 1067 mm
E. CHIMNEY REQUIREMENTS
1.
Minimum overall straight height
2.
Minimum height with offset/return
3.
Maximum height
4.
Maximum chimney length between an offset and return
5.
Maximum distance between chimney stabilizers
6.
Double offset/return minimum height
7.
Maximum unsupported chimney length between the offset and return
8.
Maximum straight unsupported chimney height above the fireplace
E36/39/42 INSTALLATION INSTRUCTIONS
B
41 in. - 1041 mm
44 in. - 1118 mm
47 in. - 1194 mm
Figure 6 - Sidewalls and Surrounds
17335 Rev L
13 ft
14.5 ft
90 ft
12 ft
35 ft
20 ft
6 ft
35 ft
07/04