HP 9840 Operation Manual page 24

Tape drive
Table of Contents

Advertisement

9840 Operator Panel
Table 2-4. Operator Panel Messages
Display
CHK (FSC)
Cleaning
(*Cleaning*)
CodCrFail1
CodCrFail2
CodeUpDate
CodUpFail1
CodUpFail2
CodUpFail3
CodUpFail4
Probable Cause
Operational failure: tape drive is
automatically reset by performing
an IPL
Cleaning tape was inserted and
the tape drive is now in the
process of cleaning
Unable to write tape
Unable to position on tape
Unreadable tape format
The firmware in the tape drive is
being updated from the NonStop
system: operator panel switches
are locked
Unable to read tape
Unable to read position on tape
Unable to read image on tape
EEPROM bad
Unreadable tape format
Not a code updated tape
9840 Tape Drive Operations Guide— 429596-002
2 -8
Operator Panel Display
Recommended Action
Wait for IPL to complete and then
retry operation.
If IPL fails, contact your service
provider to replace the tape drive.
No action is necessary.
Ensure the tape is write-enabled.
Try another tape.
Reclaim as data tape.
Retry operation.
Try another tape.
If persistent, refer to
Forcing a
Diagnostic Dump (Reset Drive)
page A-4.
No action is necessary.
Try another tape.
Try another tape.
If the problem continues, reset the
tape drive by performing an IPL.
If problem persists after the IPL,
contact your service provider to
replace tape drive
Reclaim as data tape and recreate
code tape.
Retry operation.
Try another tape.
If persistent, refer to
Forcing a
Diagnostic Dump (Reset Drive)
page A-4.
Retry with correct tape.
If persistent, refer to
Forcing a
Diagnostic Dump (Reset Drive)
page A-4.
on
on
on

Advertisement

Table of Contents
loading

Table of Contents