DO NOT attach more than one cable between any two hubs.
Figure 17
Incorrect Cabling Example: More Than One Cable Connection Between Hubs
... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
When cascading long-wave hubs, DO NOT connect the long-wave port to the short-wave
port on another hub. DO NOT connect long-wave FC-AL devices to long-wave hubs.
Figure 18
Incorrect Cabling Example: Long-Wave Port Connections to Wrong Device/Port
... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
FC-AL Device 1
In the example in Figure 18:
– The long-wave port on Hub A is incorrectly connected to Port 1, a short-wave port,
on Hub B.
– A device other than the long-wave port of another hub is attached to the long-wave
port of Hub B.
The long-wave port of Hub A should be connected to the long-wave port of Hub B.