Running Diagnostic Tests

When a problem occurs in the hub, the amber Fault LED comes on. A fault can occur for
many reasons, including:
Elevated internal temperature
Power supply failure
Fan malfunction
To determine the cause of the problem, run the hub self-test from the Main menu.
1.
Set up an RS-232 connection between the hub and a PC or dumb terminal (see Setting
Up a Connection to a PC on page 45 or Setting Up a Connection to a Dumb Terminal on
page 46).
From the Main menu, enter 1 to reset the hub and run the self-test. If the hub fails the
2.
self-test, an error number is displayed; for example:
Status of Hub Controller self-test:
A value of 0200 in the self-test represents a fan failure. Replace the fan module as
described in Replacing the Fan Module on page 88.
Any other numeric value represents an internal hub failure. Internal parts are not
replaceable. If an internal malfunction occurs, replace the hub.
WARNING
Do not attempt to open the hub chassis. Uninsulated parts inside the
chassis constitute a hazard.
After correcting any problems, enter 1 to reset the hub.
3.
For normal hub operation, the Hub Controller self-test status is displayed as " passed." For
a child hub, the Hub Controller self-test status is displayed as " Unknown."
Running Diagnostic Tests