2.
Keep the reset button pressed > 20 seconds
LED blinks very fast for one second to indicate the reset has been recognized.
»
All Parameters are reset to their default (factory settings), i.e.:
»
All network settings
ü
Baud rate 19200
ü
Interval 15 min
ü
Power management is at 100 % for all relay state combination except
ü
60 % for relay 1, 30 % for relay 2, and 0% for relay 3
Unbalanced load = 4.6 kVA
ü
Clear all unbalanced configuration
ü
Clear all power factor (cos phi) configuration
ü
This reset might require the reconfiguration from your public grid supplier.
»
13

Product Specification

rS485 INTErFACE
Max. in/output
± 5 V
voltage
Output current
≤ 250 mA
Input current
≤ 42 mA
POWEr SuPPLY (INPuT 5 V dC)
Max. input voltage +8 V
Min. input voltage
+4 V
≤ 600 mA
Max. input current
(3 W @ 5V)
approx. 185 mA
Nom. input current
(1 W @ 5 V)
AMBIENT CONdITIONS
Operating
0 °C to 40 °C
temperature range
Storage
-40 °C to 80 °C
temperature range
Relative humidity
0 % to 90 %
1) EXT. CONTROL
2) Use only the power supply adapter supplied with and suited for the SOLIVIA gateway
Operation and installation manual SOLIVIA Gateway M1 G2
ETHErNET INTErFACE (LAN)
Max. in/output
± 3 V
voltage
Output current
≤ 20 mA
Input current
≤ 20 mA
rIPPLE CONTrOL rECEIVEr
INTErFACE
1)
Input voltage
≤ 3.5 V
(ports 1 to 8)
Input current
≤ 1 mA
(ports 1 to 8)
Output voltage
≤ 3.5 V
(ports A+B)
Output current
≤ 20 mA
(ports A+B)
POWEr SuPPLY uNIT
PSU voltage
4 V to 8 V
range
Max. output power ≥ 3 W (LPS certified)
Max. output
≥ 600 mA (LPS certified)
current
2)
23