  • Page 1 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 3 Delta Energy Systems Service engineers and end users may not divulge the information contained herein or use this manual for purposes other than those strictly connected with correct use of the equipment. All information and specifications are subject to change without notice. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 4 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 5: Table Of Contents

    10.6.1.1 Feature Activation 10.6.1.2 Power Balancing Requested from the Public Grid Supplier 10.6.1.3 Grid Assignment 10.6.2 Balancing 10.7 Inverter Information 11 Delta Service Software 12 Reset Button 13 Product Specification 14 Certificates Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 6: About This Manual

    Purpose of this Manual This manual is part of the product and is only valid for the SOLIVIA Gateway M1 G2. Keep this manual in a safe place. Read this manual carefully and follow the instructions given in this manual. This manual contains important information for installing and operating the gateway.
  • Page 7: Intended Use

    (see IEC 62109-5.3.3). • Delta Energy Systems is not responsible for damage caused by failure to observe the operation and installation instructions in this manual. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 8: Scope Of Delivery

    The SOLIVIA gateway must be installed only indoors according to protection class IP20. If more than one SOLIVIA solar inverter will be connected in a chain, ensure that each inverter has a unique ID assigned in the solar inverter user interface. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 9: Connector Positions

    Ripple control receivers control the power management (power EXT. CONTROL limitation) and the power factor (cos ϕ). Connection of your SOLIVIA gateway with an internet connected network point. INPUT 5V Gateway power supply connector. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 10: Installation Procedure

    Position the bottom front end against the DIN rail until it has snapped onto the DIN rail. Push the gateway's DIN rail latch IN to lock. Figure 1: Mounting the gateway on a DIN rail Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 11: Mounting Directly To The Wall

    3. After the configuration as shown in Chapters 10.5 and 10.6 the public grid supplier is capable to remotely limit the maximum power the SOLIVIA solar inverters provide to the public grid. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 12 The cables connecting the SOLIVIA gateway with the ripple control receiver(s) should meet the following specifications: • Max. conductor cross-section: 0.5 mm (AWG20) • Min. conductor cross-section: 0.14 mm (AWG26) • Tightening torque: 0.12 – 0.15 Nm • Max. cable length: 2 m Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 13: Power Connection

    ► Repairs on defective cables should be done by qualifi ed electri- cians only! ► Only recommended and / or commercially available cables should be used. Installation Feedback NOTICE This function works only for SOLIVIA solar inverters of the 4th generation! Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 14: Led Status

    Configuration through Web Server The HTTP-server implements a browser interface allowing you to configure the gateway and to display several information. The features are: • Log in • Configuration • Display information about inverters Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 15: Access The Configuration Web Server

    If your network do not work with DHCP, please proceed as follows: Configure your computer settings manually to 192.168.0.199 Open your web browser Insert IP http://192.168.0.200/ Now go to Chapter 10.3 to see how you configure the IP of the SOLIVIA gateway. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 16: First Log In

    If your router is not supporting DHCP, you will have to enter the IP address of your SOLIVIA gateway manually. Click on "Network Settings" on the left side to open the following window where you can enter your network parameters: Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 17: Connection Settings

    NOTICE By default the gateway is configured to get its IP address from a DHCP server. To confirm your entering, click the "Submit" button. 10.4 Connection Settings Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 18: Rs485 Bus Communication

    During the usual operation the gateway collects only the data of the inverters in the inverter list. If a new inverter is connected at e.g. 2:00 pm, this inverter will only be re- cognized after a new scan (latest the next day at about noon). Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 19: Force Gateway Reset

    0.98 inductive. If the reactive power control receiver is connected to the SOLIVIA gateway as shown in figure 3 (Chapter 7.5) then the “Power Factor Control” should be configured like in figure 5. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 20: Power Management

    Please remember to save the configurations by pressing the “Submit” button. 1) This chapter is only relevant for countries, in which your public grid supplier requires a power reduction (power management), power factor control and/or power balancing. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 21: Power Balancing

    Assign the single-phase inverters to a line (L1, L2, L3) 1) This chapter is only relevant for countries, in which your public grid supplier requires a power reduction (power management), power factor control and/or power balancing. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 22: 10.6.1.1 Feature Activation

    There is no possibility to check the right mapping of the inverters to the phase except the electrician verifies the cabling of each inverter. Thus the installer should be reminded to put attention to this issue. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 23: Balancing

    MAC and IP address, the firmware (FW) version as well as the count of the flash saves. By clicking a serial number you get detailed information about an inverter. Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 24: Delta Service Software

    Wireless RS485 modem not active ü Unbalanced correction not active ü Default IPs in subnet 192.168.0.200 ü Proxy IP 0.0.0.0 ü Default password (000000) and username (Delta) ü Inverter list is cleared » Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 25: Product Specification

    Max. output Relative humidity 0 % to 90 % ≥ 600 mA (LPS certified) current 1) EXT. CONTROL 2) Use only the power supply adapter supplied with and suited for the SOLIVIA gateway Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 26: Certificates

                                     Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 27 Company name: Sing Etac Services Pty Ltd Address: 33 Mackeller Avenue Wheelers Hill Vic 3150, Australia Person responsible for making this declaration: Christina Chen Sok Kian (Name) Director (Position/Title) March 9, 2012 (Date) (Legal Signature) Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 28 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 29 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 30 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 31 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 32 Operation and installation manual SOLIVIA Gateway M1 G2...
  • Page 34 SuPPOrT - EurOPE Austria Italy service.oesterreich@solar-inverter.com supporto.italia@solar-inverter.com 0800 291 512 (Free Call) 800 787 920 (Free Call) Belgium The Netherlands support.belgium@solar-inverter.com ondersteuning.nederland@solar-inverter.com 0800 711 35 (Free Call) 0800 022 1104 (Free Call) Bulgaria Portugal support.bulgaria@solar-inverter.com suporte.portugal@solar-inverter.com +421 42 4661 333 +49 7641 455 549 Czech republic Slovakia...