(7) 12 in. WIRES
BUNDLED
MINIMUM
Figure 10.1
Intellifi re Pilot Ignition (IPI) Wiring Diagram
D.

Junction Box Installation

• Remove the screw attaching the junction box/re-
ceptacle to the outer shell, rotate the junction box
inward to disengage it from the outer shell (see
Figure 10.2).
• Pull the electrical wires from outside the appli-
ance through this opening into the valve compart-
ment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the junc-
tion box/receptacle and reassemble the junction
box/receptacle to the outer shell.
NOT
USED
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. B • 5/06
BATTERY
PACK
Figure 10.2 Junction Box Detail
NOT
USED
*Note: Appliance will not
operate unless properly
grounded
OPTIONAL
FAN
Romex
Connector
14/2WG
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.