Heat & Glo 6000GCF-IPI Owner's Manual
Heat & Glo 6000GCF-IPI Owner's Manual

Heat & Glo 6000GCF-IPI Owner's Manual

Installation and operation
Hide thumbs Also See for 6000GCF-IPI:
Table of Contents

Advertisement

Models:
6000GCF-IPI
6000GCF-IPILP
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000GCF-IPI

  • Page 1 Homes, CAN/CSA Z240MH, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 NOTICE DO NOT DISCARD THIS MANUAL • Read, understand and follow these instructions for safe installation and operation.
  • Page 2: Congratulations

    MAX. INPU T BTUH: MIN. INPU T BTUH: ORIFICE SIZE: Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
  • Page 3: Table Of Contents

    6 Termination Locations A. Vent Termination Minimum Clearances ....21 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Table of Contents 7 Vent Information and Diagrams A.
  • Page 4 D. Contact Information ......61 = Contains updated information. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08...
  • Page 5: Limited Lifetime Warranty

    • Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. Page 1 of 2 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Wood Pellet...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 4021-645A 09-01-08...
  • Page 7: Listing And Code Approvals

    Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 C. BTU Specifi cations Models...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    (1/2) in. in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Inspection The state or local gas inspector of the side wall horizon-...
  • Page 9: User Guide

    - A decorative fi rescreen. - Adjustable safety gate. Figure 2.1 General Operating Parts Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 User Guide • Install a switch lock or a wall/remote control with child protection lockout feature.
  • Page 10: Fan Kit (Optional)

    For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 F. Fixed Glass Assembly See Section 14.I. G. Remote Controls, Wall Controls and Wall...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 12: After Fireplace Is Lit

    Odor from fi replace Film on the glass Metallic noise Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 This is a result of gas combustion and temperature variations. As the fi replace warms, this condensation will disappear.
  • Page 13: Maintenance And Service

    Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Doors, Surrounds, Fronts Frequency: Annually By: Homeowner Tools needed: Protective gloves, stable work surface •...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 • Replace fi replace if fi rebox has been perforated. Control Compartment and Firebox Top Frequency: Annually By: Qualifi...
  • Page 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08...
  • Page 16: Installer Guide

    ON FLOOR OF ATTIC (SECTION 8.C) FRAMING/HEADER (SECTION 5.B) GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Installer Guide HORIZONTAL TERMINATION CAP (SECTION 10.M ) VERTICAL TERMINATION CAP (SECTION 10.J) STORM COLLAR (SECTION 10.H)
  • Page 17: Design And Installation Considerations

    1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 D. Inspect Appliance and Components • Carefully remove the appliance and components from the packaging.
  • Page 18: Framing And Clearances

    Inches Millimeters Figure 5.1 Appliance Locations Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 NOTICE: Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.
  • Page 19: Constructing The Appliance Chase

    * Adjust framing dimensions for interior sheathing (such as sheetrock). Figure 5.2 Clearances to Combustibles Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 To further prevent drafts, the wall shield and ceiling fi re- stops should be caulked with high temperature caulk to seal gaps.
  • Page 20: Mantel And Wall Projections

    OF HOOD OR TOP OF UNIT OPENING Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Combustible Mantel Legs or Wall Projections TOP VIEW Note: Clearance from fi replace opening to perpendicular wall.
  • Page 21: Termination Locations

    Over 18/12 to 20/12 ...7.5 Over 20/12 to 21/12 ...8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 TERMINATION HORIZONTAL OVERHANG VERTICAL...
  • Page 22 Figure 6.4 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 (3 FT.) = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED J** = 7 ft.
  • Page 23: Vent Information And Diagrams

    8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 7.1). Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Vertical 8-1/2 in. Horizontal Figure 7.1...
  • Page 24: Vent Diagrams

    Figure 7.3 Two Elbows INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi...
  • Page 25 1.8 m 3 ft 914 mm 9 ft 2.7 m = 20 ft (6.1 m) Max. Figure 7.5 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Minimum Maximum 1 ft 305 mm 3 ft 914 mm...
  • Page 26 fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Figure 7.8 fl ue restrictor 2. Match the amount of vertical in the system with the chart to fi...
  • Page 27 Top Vent - Vertical Termination - (continued) Two Elbows Figure 7.11 Three Elbows Figure 7.12 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 6 in. 152 mm 1 ft 305 mm 2 ft 607 mm 4 ft 1.2 m...
  • Page 28: Vent Clearances And Framing

    4 inches. • Heat shield not required if distance is more than 4 inches. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Figure 8.2 1 in. SIDE AND Fasten the shield in place using the four pilot holes pro- vided in the part.
  • Page 29: Wall Penetration Framing

    Whenever a non-combustible wall is penetrated, the wall shield fi restop is only required on one side and no heat shield is necessary. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 10 in. 3 IN. TOP...
  • Page 30: Install The Ceiling Firestop

    WARNING! Risk of Fire! DO NOT pack insu- lation around the vent. Insulation must be kept back from the pipe to prevent overheating. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 PIPE Figure 8.7 Installing Ceiling Firestop...
  • Page 31: Install Attic Insulation Shield

    These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 BEND ALL TABS INWARD 90° TO MAINTAIN CLEARANCE...
  • Page 32: Appliance Preparation

    HOLES 6 PLACES Figure 9.2 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Attach previous assembly to the top of the unit using the provided slots. The face of the sheetrock ledge assembly and the unit surround should be fl ush to each other.
  • Page 33: Securing And Leveling The Appliance

    NAILING TABS (BOTH SIDES) Figure 9.4 Proper Positioning and Securing of an Appliance Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 D. Installing the Fiberglass Gasket The fi berglass gasket supplied in the manual bag seals between the fi...
  • Page 34: Installing Vent Pipe

    Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Figure 10.1 High Temperature Silicone Sealant Figure 10.3 Figure 10.2...
  • Page 35: Assemble Slip Sections

    NOTICE: If slip section is too long, the inner and outer fl ues of the slip section can be cut to the desired length. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 C. Secure the Vent Sections •...
  • Page 36: Disassemble Vent Sections

    Figure 10.11. • Pull carefully to separate the pieces of pipe. Figure 10.10 Rotate Seams for Disassembly Figure 10.11 Align and Disassemble Vent Sections Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08...
  • Page 37: Install Metal Roof Flashing

    • Caulk the gap between the roof fl ashing and the outside diameter of the pipe. • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 HORIZONTAL OVERHANG VERTICAL Figure 10.15...
  • Page 38: Install Rf4-8

    fl ashing. Figure 10.19 Trim Rubber Boot Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Figure 10.20 Apply Sealant Figure 10.21 Slide Flashing Down, Secure & Apply Sealant...
  • Page 39: Install Vertical Termination Cap

    (1 of 3) CAULK Figure 10.23 Figure 10.23 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 I. Heat Shield Requirements for Horizontal Termination WARNING! Risk of Fire! To prevent overheating and fi re, heat shields must extend through the entire wall thick- ness.
  • Page 40: Install Horizontal Termination Cap

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield fi restop is required on the exterior side of a combustible wall.
  • Page 41: Gas Information

    • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance.
  • Page 42: Electrical Information

    110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 B. Intellifi re Ignition System Wiring • Wire the appliance junction box to 110 VAC for proper operation of the appliance.
  • Page 43: Electrical Service And Repair

    ON THE HOT SIDE Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.
  • Page 44: Junction Box Installation

    (1/4 in. male) as shown. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 GRN wire inside box NOTICE: DO NOT wire 110 VAC to wall switch.
  • Page 45: Finishing

    Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 B. Facing Material • Metal front faces may be covered with non-combustible materials only.
  • Page 46: Appliance Setup

    Remove valve assembly. Disconnect fan and remove it through the valve assembly cavity (see Figure 14.2). Figure 14.1 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 REMOVE FAN THROUGH VALVE ASSEMBLY CAVITY Figure 14.2 Figure 14.3 Rheostat Location...
  • Page 47: Install The Refractory

    fi replace. Once in place push it back so the bevel cuts sit against each other and the seam is minimized. Figure 14.5 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 STEP 3. Repeat step 2 for the right side.
  • Page 48: Install The Log Assembly

    There will be a 1/4 inch or so gap around the hump. See Figures 14.10 and 14.11. Figure 14.10 Front View Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Log Assembly: LOGS-6000G Figure 14.8 HUMP...
  • Page 49 Log #5 (SRV2103-111): center tine on the grate. The log shouldn’t cover any ports. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Figure 14.13 Top View Place log #2 on top of the left side of log #1. The bottom of this log has a slot in it Figure 14.15 Top View...
  • Page 50: Fixed Glass Assembly

    • Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model). Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 M. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed ser- vice technician at the time of installation.
  • Page 51: Troubleshooting

    C. Module is not grounded. D. Module voltage output / Valve/Pilot solenoid ohms readings. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Corrective Action Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals on module and pilot assembly.
  • Page 52 D. Damaged pilot assembly or contami- nated fl ame sensing rod. E. Module. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Possible Cause Verify all connections to wiring diagram in manual. Verify connections underneath pilot assembly are tight. Verify con-...
  • Page 53: Reference Materials

    Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. GAS LINE ACCESS Location Figure 16.1 Appliance Dimensions Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Inches Millimeters Location 28-1/2...
  • Page 54: Vent Components Diagrams

    (254 mm) DVP-AS (Attic Shield) 10 in. (254 mm) 5 in. (127 mm) DVP-HVS (Vent Support) Figure 16.2 DVP vent components Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Effective Length Pipe Inches Millimeters DVP4 DVP6 DVP12...
  • Page 55 (384 mm) 12 in. (305 mm) DVP-TRAP Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 Figure 16.3 DVP vent components Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 8 in. Heat (203 mm) Shield Term Cap Effective Trap1 Length...
  • Page 56 9-1/2 in. 14 in. DRC-RADIUS Cap Shield DVP-HSM-B Extended Heat Shield Figure 16.4 DVP vent components Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 7-3/8 in. 1-1/2 in. 17-3/4 in. 14 in. DVP-TB1 31 in. 24-5/8 in.
  • Page 57 B. Vent Components Diagrams (continued) 8-1/8 in. (206 mm) 15 in. (381 mm) Figure 16.5 DVP vent components Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 13 in. Effective Length (330 mm) 5-3/4 to 8-3/8 in. 5-1/2 in.
  • Page 58: Log Set Assembly

    6000GCF-IPI C. Service Parts Beginning Manufacturing Date: May 2006 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08...
  • Page 59: Service Parts List

    Conversion Kit LP Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 6000GCF-IPI COMMENTS PART NUMBER LOGS-6000G SRV2103-107...
  • Page 60 18"" Flexible Gas Connector Burner Orifi ce NG (#37C) Burner Orifi ce LP (#52C) Battery Pack 3 Volt Transformer Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 COMMENTS 6000GCF-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______...
  • Page 61: Contact Information

    D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 Heat & Glo, a brand of Hearth & Home Technologies Inc.