Heat & Glo 6000G Owner's Manual

Heat & glo lifestyle air conditioner user manual
Hide thumbs Also See for 6000G:
Table of Contents

Advertisement

Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.
Models:
6000G
6000G-LP
6000G-IPI
6000G-IPILP
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000G

  • Page 1 fi tter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www.heatnglo.com.
  • Page 2 IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Contact Information ......71 = Contains updated information. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 4: Listing And Code Approvals

    18,200 compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near 16,380 sinks. 18,200 16,380 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 6: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Inspect appliance and components for damage.
  • Page 7: Framing And Clearances

    REAR VENT, NO ELBOWS 56-5/8 See Section D. Mantel Projections 1829 1438 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Fire Risk Provide adequate clearance: • Around air openings • To combustibles • For service access Locate appliance away from traffi...
  • Page 8: Constructing The Appliance Chase

    Ceiling Floor (Depth) (Width) 26-5/8 1067 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Fire Risk. Odor Risk. • Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
  • Page 9: Mantel Projections

    TO CEILING Figure 3.4 Clearances to Mantel Legs or Wall Projections Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 IN T E R IO R W A L L To p V ie w...
  • Page 10: Termination Locations

    Figure 4.2 Minimum height from roof to lowest discharge Figure 4.2 specifi es minimum vent heights for various pitched roofs. Figure 4.3 Multiple Vertical Termination Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 HORIZONTAL OVERHANG 2 FT.
  • Page 11 Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 (See Note 2) Electrical Service...
  • Page 12: Vent Information And Diagrams

    3. Vertical terminations are measured to bottom of termi- nation cap. 4. Horizontal pipe installed level with no rise. Figure 5.2 DVP Pipe Effective Length Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Vertical 8-1/2 in. Horizontal...
  • Page 13 90 elbow, to allow the vent pipe to clear the top standoffs. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi...
  • Page 14 • When using DVP-HRC-SS and DVP-HRC-ZC- SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Max. 1 ft. 305 mm 2 ft.
  • Page 15 (see Figure 5.8). Figure 5.8 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 S H IE L D F L U E B R E A K...
  • Page 16 5. Reinstall the Exhaust Shield. REAR VENT Restrictor Restrictor Restrictor Figure 5.10 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 S E T T IN G S Maximum Elbow only 2 ft. 610 mm 6 in.
  • Page 17 18 ft. = 20 ft (6.1 m) Maximum IN S TA L L E D H O R IZ O N TA L LY Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Minimum 1 ft. 2 ft.
  • Page 18 No Elbow Figure 5.13 One 45º Elbow Do not use a 45 Use two 90 elbows instead. Figure 5.14 elbow in corner installations. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 = 16 in. (406 mm) Maximum...
  • Page 19 3 ft. 914 mm 3 ft. 3 ft. 914 mm 4 ft. = 40 ft (12.2 m) Maximum Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Minimum 1 ft. 305 mm 2 ft. 152 mm 2 ft.
  • Page 20 Figure 5.17 Two Elbows Figure 5.18 IN S TA L L E D H O R IZ O N TA L LY Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Minimum 6 in. 152 mm 2 ft.
  • Page 21 5 ft. 1.5 m 7 ft. 2.1 m 8 ft 2.4 m = 8 ft (2.4 m) Max. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Minimum 6 in. 152 mm 2 ft. 610 mm 1 ft.
  • Page 22: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 6.2 Exterior Wall Hole Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 10 in. 10 in.
  • Page 23: Vertical Penetration Framing

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING Figure 6.4 Installing the Attic Shield Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 ATTIC ABOVE PIPE 10 in. (254 mm) 9 in. (229 mm)
  • Page 24: Install Attic Insulation Shield

    BEND ALL TABS INWARD 90° TO MAINTAIN CLEARANCE AND PREVENT INSULATION FROM FALLING INSIDE Figure 6.5 Attic Insulation Shield Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 LASER-ETCHED INSERT 3 CUT LINES SCREWS BEND 3 TABS...
  • Page 25: Appliance Preparation

    Note: Once the vent cap has been removed it cannot be reattached. Proceed to Section 7. C. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 CAUTION Sharp Edges • Wear protective gloves and safety...
  • Page 26: Installing The Non-Combustible Board

    • Do NOT notch into the framing around the appliance spacers. Failure to keep insulation, framing or other material away from the appliance may cause fi re. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Fire Risk.
  • Page 27: Install The Optional Heat-Zone-Gas Kit

    fi replace with 3 screws. Note: Do this BEFORE fi nal positioning of fi replace. 3. Determine the location for the air register/fan housing assembly. Reference the Heat-Zone-Gas kit instructions for the remaining installation steps. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 28: Installing Vent Pipe (Dvp And Slp Pipe)

    Figure 8.1 High Temperature Silicone Sealant Figure 8.2 Note: unintentional disconnection. Figure 8.4 Seams Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Lances Lances Figure 8.3 Make sure that the seams are not aligned to prevent...
  • Page 29: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Pilot hole Pilot hole...
  • Page 30: Secure The Vent Sections

    Figure 8.11. • Pull carefully to separate the pieces of pipe. Figure 8.10 Rotate Seams for Disassembly Figure 8.11 Align and Disassemble Vent Sections Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 31: Install Decorative Ceiling Components (Slp Only)

    PATTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 8.12 Figure 8.13 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 LEVEL CATHEDRAL CEILING SUPPORT BOX 2 in. (51 mm) MIN. BELOW FINISHED CEILING...
  • Page 32: Install Metal Roof Flashing

    Figure 8.16 Assembling the Storm Collar Figure 8.16 Assembling the Storm Collar Figure 8.17 Assembling the Storm Collar Around the Pipe Figure 8.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 CAULK...
  • Page 33: Install Rf4-8

    Figure 8.20 Apply Sealant Figure 8.21 Slide Flashing Down, Secure & Apply Sealant FLASHING OVER SHINGLES Figure 8.22 Installation Complete Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 APPLY SEALANT TOP & PARTIAL SIDES SILICONE SEALANT (TOP OF BOOT)
  • Page 34: Install Vertical Termination Cap

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 35: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 HEAT SHIELD OR EXTENDED...
  • Page 36: Gas Information

    Propane 11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 37 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 38: Electrical Information

    Battery polarity must be correct or module damage will occur. Optional Accessories Requirements Wiring for optional accessories should be done now to avoid reconstruction. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 CAUTION...
  • Page 39: Standing Pilot Ignition System Wiring

    Verify proper operation after servicing. B R N R E D O N /O F F P IG G Y B A C K W IR E Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 INTERMITTENT PILOT IGNITOR THERMOSTAT WIRE...
  • Page 40: Junction Box Installation

    Figure 10.4 Junction Box Detail MINIMUM 14-3 WITH GROUND JUNCTION BOX Figure 10.5 Junction Box Wired to Wall Switch Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Romex Connector 14/2WG Copper ground attached...
  • Page 41: Finishing

    • Seal joints between the fi nished wall and appliance top and sides using only a 300º F minimum sealant. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 NON-COMBUSTIBLE ZONE (Shaded areas) 41 in.
  • Page 42: Finishing Material

    11.5 11.7 Figure 11.6 Inside fi t door 1-2 IN. THICK FINISHING MATERIAL Figure 11.7 Operable hinge door Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 ELBOW HEAT SHIELD DOOR 37 in. (Outside door width) 37-1/4 in.
  • Page 43: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING Explosion Risk. • Follow ember placement instructions in manual.
  • Page 44: Positioning The Logs

    1/4 inch or so gap around the hump. See Figures 12.4 and 12.5. Figure 12.4 Front View Figure 12.2 Figure 12.3 Figure 12.5 Top View Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Log Assembly: LOGS-6000G HUMP HUMP SMALLER SMALLER...
  • Page 45 Place log #4 on top of the right side of log #1. The bottom of this log has a Figure 12.13 Top View Place log #5 in front of log #3 the notch in the bottom of this log rests over Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Top View...
  • Page 46: Glass Assembly

    When fi nished tighten wing nut. Figure 12.15 Shutter Settings Burner Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 AIR SHUTTER WING NUT 1/8 in. Full Open...
  • Page 47: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 48: Lighting Instructions (Ipi)

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 LIGHTING INSTRUCTIONS (IPI) 1. Turn off all electric power to the appliance.
  • Page 49: For Your Safety

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 LIGHTING INSTRUCTIONS 1. Open control access panel.
  • Page 50: After Appliance Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 CAUTION CAUTION •...
  • Page 51: Troubleshooting

    Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Corrective Action...
  • Page 52 Insuffi cient oxygen being supplied. and lifts off burner. Possible Cause Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Corrective Action Turn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
  • Page 53: Intellifi Re Ignition System

    fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or too high an inlet pressure can cause pilot fl ame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Corrective Action...
  • Page 54 1/8 in. Verify module is securely grounded to metal chassis of appliance. Verify battery voltage is at least 2.7 volts. Replace batteries if voltage is below 2.7. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Corrective Action...
  • Page 55: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 CAUTION Handle glass assembly with care. Note: Clean glass after initial 3-4 hours operation.
  • Page 56 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Maintenance Tasks Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 57: Reference Materials

    FRONT VIEW Inches Millimeters Location 1041 36-1/8 33-1/2 34-5/8 2-3/8 26-7/8 8 dia 21-1/2 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 ELECTRICAL ACCESS RIGHT SIDE Inches Millimeters 11-5/8 28-1/2 14-1/4 8 dia 2-1/8 6-7/8 39-3/8...
  • Page 58: Vent Components Diagrams

    ( 3 5 6 m m ) 12 in . ( 3 0 5 m m ) Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 1 0 -1 /2 in . ( 2 6 7 m m ) 4 -7 /8 in .
  • Page 59 DVP-TRAPK1 DVP-HPC1 Figure 16.3 DVP vent components 8 in. Heat (203 mm) Shield Effective Length Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Minimum Maximum Term Cap Effective Length Effective Length 3-1/8 in. 4-5/8 in. Trap1...
  • Page 60 (181 mm) 5-3/4 in. (146 mm) 13-7/8 in. (352 mm) 14 in. (356 mm) Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 31 in. (787 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak 11-7/8 in.
  • Page 61 (305 mm) DVP-TB1 Basement 14 in. (356 mm) 7-1/8 in. 8-3/4 in. (222 mm) Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 7-3/8 in. (187 mm) 1-1/2 in. (38 mm) 17-3/4 in. 14 in. (451 mm)
  • Page 62 SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 5-1/2 in. 8-3/8 in. 140 mm 213 mm 3°...
  • Page 63 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 RF4-8 Roof Flashing Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 6-1/2 in. 165 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in.
  • Page 64 (For use on IntelliFire appliances only) 26 in. 660 mm DVP-2SL SL-2DVP DVP-HSM-B Adapter Adapter Extended Heat Shield SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Thimble-Black Black Figure 16.8 SLP Series Vent Components Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 65: Service Parts

    6000G, 6000G-IPI C. Service Parts Beginning Manufacturing Date: May 2006 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08...
  • Page 66 Pilot Orifi ce, NG Pilot Orifi ce, LP Regulator, NG Regulator, LP Additional service part numbers on following page. Standing Pilot IPI Ignition Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 6000G, 6000G-IPI COMMENTS PART NUMBER LOGS-6000G SRV2103-107 SRV2103-108...
  • Page 67 Flex Ball Valve Assembly Piezo Ignitor Valve, NG Valve, LP Remote Pigtail Wire Wire Assembly Service Parts Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ COMMENTS PART NUMBER 2103-010 2103-011...
  • Page 68 Thermostat Wire Assembly 3V Transformer Remote Wire Assembly Battery Pack Service Parts Service Parts Diagram Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 6000G-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ COMMENTS PART NUMBER...
  • Page 69: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed...
  • Page 70 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 4021-645A 09-01-08...
  • Page 71: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2008 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 • Leave this manual with party responsible for use and operation.