Electrical Information; Recommendation For Wire; Section 10: Electrical Information A. Recommendation For Wire; Connecting To The Appliance - Heat & Glo 6000GL-IPI-R Owner's Manual

Hide thumbs Also See for 6000GL-IPI-R:
Table of Contents

Advertisement

10

Electrical Information

A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junc-
tion box for use of optional accessories and for proper
operation of the appliance (Intellifi re ignition).
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
B.

Connecting to the Appliance

WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety lock-
out and may cause explosion.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation
of appliance.
• Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
36
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. B • 5/06
C. Intellifi re Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not includ-
ed). Batteries can be placed in the battery pack while using
the 3 volt AC transformer. Batteries shouldn't be placed
into the holder until needed. The higher temperatures will
shorten their life.
CAUTION
Battery polarity must be correct or module damage will
occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105
rated wire.
• Wire must have high temperature insulation.
WARNING
O
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000gl-ipi-s6000gl-ipilp-r6000gl-ipilp-s