Termination Locations; Vent Termination Minimum Clearances - Heat & Glo 6000GL-IPI-R Owner's Manual

Hide thumbs Also See for 6000GL-IPI-R:
Table of Contents

Advertisement

4

Termination Locations

A.

Vent Termination Minimum Clearances

WARNING
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or
other materials.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
(See Figure 4.4 for specifi c clearances)
Figure 4.1
10
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. B • 5/06
Roof Pitch
Flat to 6/12 ......................................................... 1.0*
Over 6/12 to 7/12 ................................................ 1.25*
Over 7/12 to 8/12 ................................................ 1.5*
Over 8/12 to 9/12 ................................................ 2.0*
Over 9/12 to 10/12 .............................................. 2.5
Over 10/12 to 11/12 ............................................ 3.25
Over 11/12 to 12/12 ............................................ 4.0
Over 12/12 to 14/12 ............................................ 5.0
Over 14/12 to 16/12 ............................................ 6.0
Over 16/12 to 18/12 ............................................ 7.0
Over 18/12 to 20/12 ............................................ 7.5
Over 20/12 to 21/12 ............................................ 8.0
* 3 foot minimum in snow regions
Figure 4.2
Minimum Height from Roof to
Lowest Discharge Opening
Figure 4.2 specifi es minimum vent heights for various
pitched roofs.
GAS, WOOD OR FUEL
OIL TERMINATION
GAS
TERMIN ATION
Gas Termination
A
6 in.
Figure 4.3
Multiple Vertical Termination
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
H (Min.) Ft.
20 IN.
(MINIMUM) TO
PERPENDICULAR
WALL
(GAS ON LY)
Wood & Fuel Oil Termination
20 in.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000gl-ipi-s6000gl-ipilp-r6000gl-ipilp-s