Extension of Detector Cable
3
The standard Detector Cable is 10m. The Detector Cable shall be
extended by referring to the Table below. Use a device such as a Pull-box
if necessary.
Detector Cable length X [ m ]
Nominal sectional area
0.2 [ mm
2
]
0.3 [ mm
2
]
0.5 [ mm
2
]
0.75 [ mm
2
]
Pull-box, etc.
Max. cable length X [ m ]
10 [m]
20 [m]
40 [m]
50 [m]
4

Operation Panel

Move the digit to be entered using the right and left arrow buttons
( 0.1 digit
1 digit
10 digit
At this time, the selected digit blinks.
Enter a numerical value ( 0, 1, 2, ..., 9 ) into the selected digit using the
upper and lower arrow buttons
value and
button decreases the value.
The CAL button
carries out calibration.
Press the calibration button for 2 seconds or more to carry out calibration.
The MODE button
makes sure of each setting. To change the setting
value, select an item and then keep pressing the MODE button for 2
seconds or more.
The CLEAN button
wipes the Detector Windows.
To wipe the Detector Windows, press the CLEAN button for 2 seconds or
more.
The CANCEL button
to the condition prior to change.
The ENT button
saves the numerical values entered and terminate the
setting change operation.
Press the right and left arrow buttons
Fine Adjustment of Signal Output Low Limit ( 4mA ) .
Press the upper and lower arrow buttons
Fine Adjustment of Signal Output High Limit ( 20mA ) .
1000 digit ) .
100 digit
.
button increases a numeric
cancels the setting change operation and return
simultaneously to carry out
simultaneously to carry out