Technical Specifications - HP ProLiant DL120 Specification

Hewlett-packard generation 5 (g5) server quickspecs
Hide thumbs Also See for ProLiant DL120:

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions (H x W x D)
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
DA - 13014
North America — Version 6 — August 11, 2008
1.69 x 17.64 x 27.5 in (4.30 x 44.80 x 69.85 cm)
Maximum
(two hard drives, power
supply, and processor
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Range Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls
- Click on the system of interest. Example: DL120 G5
- Follow the instructions of the next screens.
Rated Steady-State Power 350 W (at 115/230 VRMS),
Maximum Peak Power
Non-operating
Operating
Non-operating
HP ProLiant DL120 Generation 5 (G5)
HP ProLiant DL120 Generation 5 (G5)
HP ProLiant DL120 Generation 5 (G5)
HP ProLiant DL120 Generation 5 (G5)
32.40 lb (14.70kg)
31.00lb (14.00kg)
90 - 132 VAC,
180 - 264 VAC
6 A (at 100 VAC),
3 A (at 200 VAC)
47 to 63 Hz
<500W @115/230 VRMS (For frequency only)
1194 BTU/hr (at 115/230 VRMS)
350 W (at 115/230 VRMS)
350 W (at 115/230 VRMS),
350 W (at 115/230 VRMS)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 300 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Page 25