4.1.6
TWO ENDS DEVICES CANNOT CONNECT
Both sides of devices in the same Ethernet broadcast domain, checking both side
of device IP address should on dual relationship. Check MAC address is unique
(include other device on the same network); Using Ping command to check network,
checking bandwidth is sufficient or not.
If two sides of devices are not in same Ethernet segment, checking device IP
default gateway setting, IP address, IP address mask, and check conflicts of MAC
address or IP address;
address can be set by NMS, MAC address set by manufacture.
Check both ends of the device VLAN setting should be in accordance with
eachother.
4.1.7
Both Sides devices of E1/T1 have slip
Check both sides devices AN-TDM-IP-1E1 E1/T1 clock setting, at least one of
device should be Master-Clock.
Check AN-TDM-IP-1E1/2E1-A time mode setting. If both sides of the E1/T1
equipment are not in the state of the synchronization, units timing model must be
adaptive timing, not loop timing.
At beginning of startup, slip is normal.
5.
Web Manager
AN-TDM-IP-1E1/2E1-A support Web Server to monitoring devices. Login
Web Server need Username and Password, the default Username and password are
"admin", as below picture showed, at System setting you can change it.