B-2 Power Cord Requirements
4. The attachment plug must be an earth-grounding type with
a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.
1. The cord must be MITI approved.
2. The flexible cord must be a VCT or VCT F 3-conductor cord
with a minimum conductor size of 1.50 square millimeters.
3. The cord must have a rated current capacity of 12A.
4. The attachment plug must be an earth-grounding type
JIS 8303 (15A, 125V) configuration.
1. The cord fittings must bear the certification mark of the
agency responsible for evaluation in a specific country.
Acceptable agencies include:
BSI (United Kingdom)
CEBEC (Belgium)
DEMKO (Denmark)
EANSW (Australia)
IMQ (Italy)
KEMA (The Netherlands)
NEMKO (Norway)
2. The flexible cord must be of a HAR (harmonized) type
HO5VV-F 3-conductor cord with a minimum conductor size
of .03 square inches (1.0 square millimeters).
3. The cord must have a current capacity of at least 10 Amperes
and a nominal voltage rating of 100-125 or 220-250 VAC.
OVE (Austria)
SEMKO (Sweden)
SETI (Finland)
SEV (Switzerland)
UTE (France)
VDE (Germany)