Mobile Home Installation
Secure the heater to the floor using the two holes in the pedestal. If the unit is on a combustible
surface, you will need to drill matching holes in the floor protection that you choose (see Floor
Protection section). Do not disturb the structural integrity of the home, and be sure the unit is
permanently electrically grounded to the chassis of your home. Remember that outside combustion
air is mandatory, and not to install the unit in a sleeping room of the home.
Be sure to install in accordance with 24 CFR, Part 3280 (HUD).
Outside Air Connection
When installing this model in a mobile home or double wide it is necessary to supply the
combustion air into the unit from outside the dwelling. NOTE: THIS STOVE IS MOBILE HOME AND
DOUBLE WIDE APPROVED (WITH OUTSIDE AIR HOOK-UP) FOR THE PEDESTAL MODEL ONLY
– NOT FOR LEG MODELS.
This can be done by running a thin gauge three inch (3") pipe (flex or rigid) from the air inlet pipe
located on the rear of the stove through the floor or wall (measure pipe to ensure you obtain the
correct size). The outside end of this pipe should be covered in some manner (i.e. screen) to keep it
clear of foreign matter. Be sure to keep it above the snowdrift line and clear of leaves and other
debris. If you are installing this stove in a regular dwelling this connection is not necessary, but is
recommended in air-tight homes.