Danfoss DHP-A User Manual page 16

Domestic heat pumps
Table of Contents

Advertisement

User Guide
N
Adjust the heat curve in the HEAT CURVE menu as follows:
HEAT CURVE
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEAT STOP
The heat curve and therefore the indoor temperature can be affected by changing the ROOM value. If the
ROOM value is used to affect the system's heat curve, the heat curve does not become steeper or flatter, as it
does when the CURVE value changes. Instead the entire heat curve is moved by 3°C for every degree change of
the ROOM value.
N
Change the ROOM value as follows:
1. Press either the + or - button once to open and change the ROOM value.
2. Increase or decrease the ROOM value using the + or - buttons to change the indoor temperature.
3. Wait ten seconds or press the left button once to exit the menu.
16
Domestic heat pumps
High temperatures in an underfloor heating system can damage parquet
floors.
40˚C
22˚C
70˚C
0˚C
0˚C
0˚C
17˚C
For a temporary increase or decrease of the indoor temperature, adjust the
ROOM value.
VUGFE102
1. Open the HEAT CURVE menu in the INFORMA-
TION menu.
2. Select the parameter required using the + or –
button.
3. Open the parameter by pressing the right but-
ton once.
4. Increase or reduce the value with the + or - but-
ton.
5. Press the left button three times.
Danfoss Heating Solutions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents