2.0 Checking Voltage Selection

The standard Printer is configured for 115 VAC
phase 50/60 Hz with a properly-grounded outlet. A small sticker
next to the power cord connection indicates the power requirements.
For international markets, there is a 230 VAC version available. If
you are uncertain about the configuration of your Printer, or the
outlet you are connecting to, check with a qualified service
technician to verify the installation before connecting power.
2.1 Power Up Self-Test
Once labels are installed in the Printer as described in Section 1.6, a
Self-Test should be performed. The Printer will power up in the
Self-Test Mode when the feed button is pressed as the Printer is
being turned on. Initial power up will take approximately 7 seconds.
The Printer should be loaded with 4.25" (108 mm) wide stock
whenever this test is conducted. The Self-Test prints across the
entire width of the Printhead. Expect a brief hesitation of up to 15
seconds before the Self-Test begins to print.