Drum
23
8.2 Replacement of the belt
Disconnect the power to the machine.
Demount the back panel.
Remove the belt (A) and put the new belt in position. Check the belt tension with a frequency
meter or similar. The frequency shall be 70 Hz ± 5. Adjust if necessary with the right screw in
the slotted hole.
A
fig.7579
⑯
Remount the back panel.
Connect the power to the machine.