Instructions For Local Firmware Upgrade Using Tftp Server; Configuration File Download; Firmware And Configuration File Prefix And Postfix; Managing Firmware And Configuration File Download - Grandstream Networks HT701 User Manual

Ht70 series analog telephone adaptor
Hide thumbs Also See for HT701:
Table of Contents

Advertisement

3- From the HT70X web interface (Advanced Settings page) you can browse your hard drive and
select the folder you previously saved the file (ht70xfw.bin)
4- Click "Upload Firmware" and wait few minutes until the new program is loaded.
Note: Always check the status page to see that the program version has changed.

Instructions for local firmware upgrade using TFTP server:

1. Unzip the file and put all of them under the root directory of the TFTP server.
2. Put the PC running the TFTP server and the HT701 device in the same LAN segment.
3. Please go to File -> Configure -> Security to change the TFTP server's default setting from
"Receive Only" to "Transmit Only" for the firmware upgrade.
4. Start the TFTP server, in the phone‟s web configuration page
5. Configure the Firmware Server Path with the IP address of the PC
6. Update the change and reboot the unit
End users can also choose to download the free HTTP server from http://httpd.apache.org/ or use
Microsoft IIS web server.

Configuration File Download

Grandstream SIP Device can be configured via Web Interface as well as via Configuration File through
TFTP or HTTP/HTTPS. "Config Server Path" is the TFTP or HTTP/HTTPS server path for configuration
file. It needs to be set to a valid URL, either in FQDN or IP address format. The "Config Server Path" can
be same or different from the "Firmware Server Path".
A configuration parameter is associated with each particular field in the web configuration page.
parameter consists of a Capital letter P and 1 to 3 (Could be extended to 4 in the future) digit numeric
numbers. i.e., P2 is associated with "Admin Password" in the ADVANCED SETTINGS page. For a
detailed parameter list, please refer to the corresponding firmware release configuration template.
When Grandstream Device boots up or reboots, it will issue request for configuration file named
"cfgxxxxxxxxxxxx", where "xxxxxxxxxxxx" is the MAC address of the device, i.e., "cfg000b820102ab". The
configuration file name should be in lower cases.

Firmware and Configuration File Prefix and Postfix

Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix and
Postfix. This makes it the possible to store ALL of the firmware with different version in one single directory.
Similarly, Config File Prefix and Postfix allows device to download the configuration file with the matching
Prefix and Postfix. Thus multiple configuration files for the same device can be stored in one directory.
In addition, when the field "Check New Firmware only when F/W pre/suffix changes" is set to "Yes", the
device will only issue firmware upgrade request if there are changes in the firmware Prefix or Postfix.

Managing Firmware and Configuration File Download

When "Automatic Upgrade" is set "Yes, every" the auto check will be done in the minute specified in this
field. If set to "daily at hour (0-23)", Service Provider can use P193 (Auto Check Interval) to have the
devices do a daily check at the hour set in this field with either Firmware Server or Config Server. If set to
"weekly on day (0-6)" the auto check will be done in the day specified in this field. This allows the device
Grandstream Networks, Inc.