EMI MEASUREMENT AND TEST REPORT
th
5
Floor, R2-A Building, South District of Hi-Tech Industrial Park, Shenzhen, P. R. China, P. C. 518057
This Report Concerns:
Report Number:
Note: The test report is specially limited to the use of the above client company and the
PDF created with FinePrint pdfFactory Pro trial version
FCC PART 15 CLASS B
Grandstream Networks,Inc.
Original Report
Test Engineer:
Jandy Su
RSZ03101401
Test Date:
November 7, 2003
Reviewed By:
Bay Area Compliance Lab Corp. ShenZhen
Prepared By:
Suite C, 41-D Electronics Science & Technology Building,
No. 2070 Shennanzhong Rd ShenZhen,
Guandong 518031, P.R. China
Tel: (755) 83296449
Fax: (755) 83273756
product model. It may not be duplicated without prior written consent of Bay Area
Compliance Laboratory Corporation. This report must not be used by the client to
claim product endorsement by NVLAP or any agency of the U.S. Government
For
Model: HT-286
November 7, 2003
Equipment Type:
HT-286 Line Adapter
http://www.pdffactory.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HT-286 and is the answer not in the manual?

Questions and answers

Summary of Contents for Grandstream Networks HT-286

  • Page 1 Floor, R2-A Building, South District of Hi-Tech Industrial Park, Shenzhen, P. R. China, P. C. 518057 Model: HT-286 November 7, 2003 This Report Concerns: Equipment Type: Original Report HT-286 Line Adapter Test Engineer: Jandy Su Report Number: RSZ03101401 Test Date:...
  • Page 2: Table Of Contents

    Grandstream Networks,Inc. Model: HT-286 TABLE OF CONTENTS 1 - GENERAL INFORMATION..........................4 1.1 P (EUT)................4 RODUCT ESCRIPTION FOR QUIPMENT NDER 1.2 O ................................4 BJECTIVE 1.3 R ) ........................4 ELATED UBMITTAL RANT 1.4 T ............................4 ETHODOLOGY 1.5 T ..............................
  • Page 3 Grandstream Networks,Inc. Model: HT-286 EUT – C ............................22 OMPONENT APPENDIX D – BLOCK DIAGRAM/SCHEMATICS/PARTS LIST..............23 APPENDIX E – USER MANUAL..........................24 Report # RSZ03101401 Page 3 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version...
  • Page 4: General Information

    1.1 Product Description for Equipment Under Test (EUT) The Grandstream Networks,Inc. ’s product, model HT-286 or the "EUT" as referred to in this report is a HT-286 Line Adapter which measures approximately 9.5cm L x 6.5cm W x 2.5cm H, rated input voltage: AC 120V /60Hz..
  • Page 5: Test Equipment List

    Grandstream Networks,Inc. Model: HT-286 The test site has been approved by the FCC and VCCI for public use and is listed in the FCC Public Access Link (PAL) database. Additionally, Bay Area Compliance Laboratory Corporation is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (NVLAP).
  • Page 6: Local Support Equipment List And Details

    Grandstream Networks,Inc. Model: HT-286 1.8 Local Support Equipment List and Details Manufacturer Description Model Serial Number FCC ID Telephone BK-8137 1.9 External I/O Cabling Cable Description Length (M) From/Port Unshielded power Cable with cord Power LAN Cable Customer encloser Report # RSZ03101401...
  • Page 7: System Test Configuration

    EUT being normal operation. 2.3 Special Accessories As shown in section 2.6, interface cable used for compliance testing is shielded as normally supplied by Grandstream Networks,Inc., and its respective support equipment manufacturers. 2.4 Block Diagram Please refer to the Appendix D.
  • Page 8: Configuration Of Test System

    Grandstream Networks,Inc. Model: HT-286 2.6 Configuration of Test System Customer enclouse Telephone 2.7 Test Setup Block Diagram Power Cable LAN Cable LISN 10cm Customer enclouse Telephone 1.5 Meter Report # RSZ03101401 Page 8 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 9: Conducted Emissions Test Data

    Grandstream Networks,Inc. Model: HT-286 3 - CONDUCTED EMISSIONS TEST DATA 3.1 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, and LISN. Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any conducted emissions measurement at BACL is +2.4 dB.
  • Page 10: Conducted Emissions Test Data

    Grandstream Networks,Inc. Model: HT-286 3.5 Conducted Emissions Test Data Date of Test : November 7, 2003 Temperature : 25 HT-286 Line Adapter Humidity : 70 HT-286 Operating Mode : running Test Engineer: Jandy Su FCC PART 15 C ONDUCTED MISSIONS...
  • Page 11: Plot(S) Of Conducted Emissions Test Data

    Grandstream Networks,Inc. Model: HT-286 3.7 Plot(s) of Conducted Emissions Test Data Plot(s) of Conducted Emissions Test Data is presented hereinafter as reference. Report # RSZ03101401 Page 11 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version...
  • Page 12 Grandstream Networks,Inc. Model: HT-286 LAN cable: Report # RSZ03101401 Page 12 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 13: Radiated Emission Data

    Grandstream Networks,Inc. Model: HT-286 4 - RADIATED EMISSION DATA 4.1 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability.
  • Page 14: Test Procedure

    B. The equation for margin calculation is as follows: Margin = Corr. Ampl. - FCC Class B Limit 4.6 Radiated Emissions Test Result Date of Test : November 7, 2003 Temperature : 25 HT-286 Line Adapter Humidity : 70 Operating Mode : running HT-286 Test Engineer:...
  • Page 15: Appendix A - Fcc Product Labeling And Warning Statement

    Grandstream Networks,Inc. Model: HT-286 APPENDIX A - FCC PRODUCT LABELING AND WARNING STATEMENT Proposed FCC Label Format For Home or Office Use Specifications: Text is Black or white in color and is left justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT.
  • Page 16: Appendix B - Test Setup Photographs

    Grandstream Networks,Inc. Model: HT-286 APPENDIX B - TEST SETUP PHOTOGRAPHS Telephone Conducted Emission - Front View Conducted Emission - Side View Report # RSZ03101401 Page 16 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version...
  • Page 17: Telephone Conducted Emission - Front View

    Grandstream Networks,Inc. Model: HT-286 Telephone Conducted Emission - Front View Telephone Conducted Emission - Side View Report # RSZ03101401 Page 17 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 18: Radiated Emission - Front View

    Grandstream Networks,Inc. Model: HT-286 Radiated Emission - Front View Mode: Radiated Emission - Rear View Report # RSZ03101401 Page 18 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 19: Appendix C - Eut Photographs

    Grandstream Networks,Inc. Model: HT-286 APPENDIX C - EUT PHOTOGRAPHS EUT - Front View (1) EUT - Rear View (2) Report # RSZ03101401 Page 19 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version...
  • Page 20: Eut - Front View (3)

    Grandstream Networks,Inc. Model: HT-286 EUT - Front View (3) EUT - Rear View (4) Report # RSZ03101401 Page 20 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 21: Eut - Uncovered View

    Grandstream Networks,Inc. Model: HT-286 EUT – Uncovered View EUT – PCB View (1) Report # RSZ03101401 Page 21 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 22: Eut - Pcb View (2)

    Grandstream Networks,Inc. Model: HT-286 EUT – PCB View (2) EUT – Component View Report # RSZ03101401 Page 22 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 23: Appendix D – Block Diagram/Schematics/Parts List

    Grandstream Networks,Inc. Model: HT-286 Appendix D – Block Diagram/Schematics/Parts List Report # RSZ03101401 Page 23 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...
  • Page 24: Appendix E – User Manual

    Grandstream Networks,Inc. Model: HT-286 Appendix E – User Manual Report # RSZ03101401 Page 24 of 24 FCC Part 15 Class B Doc Report PDF created with FinePrint pdfFactory Pro trial version http://www.pdffactory.com...