US / Canada J-340 2-Pump Model (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 50A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
** In 30A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
Export J-310 / J-320 / J-330 1-Pump Models (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In the 30A configuration, the heater will operate at the same time as
the main jets pump. This is the factory setting.
** In the 20A configuration, the heater will not operate at the same time
as the main jets pump.
Export J-340 2-Pump Model (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 30A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed. This
is the factory setting.
** In 20A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
240V/50A*
240 VAC
3
60Hz
36A
50A, 2-Pole
230V/30A*
230 VAC
3
50Hz
21A
30A
230V/30A*
230 VAC
3
50Hz
23A
30A
240V/30A**
240 VAC
3
60Hz
24A
30A, 2-Pole
230V/20A**
230 VAC
3
50Hz
15A
20A
230V/20A**
230 VAC
3
50Hz
15A
20A