Msa2000 3.5 12-Drive Enclosure; Cache; Transportable Compactflash - HP StorageWorks 2324fc User Manual

Carrier-grade modular smart array
Hide thumbs Also See for StorageWorks 2324fc:
Table of Contents

Advertisement

MSA2000 3.5 12-drive enclosure

1
1
Power supplies
2
Power switches
3
SAS In port (connects to a controller enclosure)
NOTE:
The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later.
For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide
located on the MSA2000 Software Support/Documentation CD shipped with your product or at
http://hp.com/support/manuals.

Cache

To enable faster data access from disk storage, the following two types of caching are performed:
Posted-write caching. The controller writes user data in the cache memory on the module rather than
directly to the drives. Later, when the storage system is idle, the controller writes the data to the drive
array.
Read-ahead caching. The controller detects sequential array access, reads ahead into the next
sequence of data, and stores the data in the read-ahead cache. Then, if the next read access is for
cached data, the controller immediately loads the data into the system memory, avoiding the latency of
a disk access.

Transportable CompactFlash

During a power loss or array controller failure, data stored in cache is saved off to non-volatile memory
(CompactFlash). This data is then written to disk after the issue is corrected. To protect against writing
incomplete data to disk, the image stored on the CompactFlash is verified before committing to disk.
In single-controller configurations, if the controller has failed or does not start, and the Cache Status LED is
on or blinking, the CompactFlash will need to be transported to a replacement controller to recover data
not flushed to disk. (See
CompactFlash
2
3
Controller failure in a single-controller configuration
HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide
4
5
6
4
Service port (used by service personnel only)
5
SAS Out port (connects to another drive enclosure)
6
Optional I/O module
2
1
for more information.)
19

Advertisement

Table of Contents
loading

Table of Contents