Advertisement

Quick Links

Installation and
Reference Guide
HP J2610B
HP AdvanceStack 10Base-T Hub-8U

Advertisement

Table of Contents
loading

Summary of Contents for HP AdvanceStack Hub-8U J2610B

  • Page 1 Installation and Reference Guide HP J2610B HP AdvanceStack 10Base-T Hub-8U...
  • Page 3 You can download: j3133a.exe HP AdvanceStack 8U/16U SNMP firmware: from the HP BBS, HP FTP Library Service, CompuServe, and the World Wide Web. After you download the file, extract the file by typing filename /x. For example j3133a.exe /x HP BBS Set your modem to N-8-1, set speed up to 14400 bps, and with your telecom- munication program (e.g., Windows Terminal) dial (208) 344-1691 to get the...
  • Page 5 HP AdvanceStack Hub-8U Installation and Reference Guide...
  • Page 6 A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be ob- tained from your HP Sales and Service Office or authorized dealer. 8000 Foothills Boulevard MS 5551 Roseville, California 95747-5551...
  • Page 7 HP AdvanceStack Hub-8U At A Glance The HP J2610B AdvanceStack Hub-8U is a multiport repeater with eight twisted-pair network ports. With this hub, you can connect computers and other devices together in an unshielded twisted-pair cable network. This hub is compliant with the IEEE 802.3 Type 10Base-T standard and supports both...
  • Page 8 MDI/MDI-X switch port LEDs for port 1 Hub status LEDs Twisted-pair ports Back of the Hub cover plate over expansion slot for HP AdvanceStack 8U/16U SNMP DC power cover plate over slot for HP AUI Module receptacle and Transceiver Modules...
  • Page 9 “straight-through” twisted-pair cable in both cases. Upgradeable Design A management slot in the back of the hub enables you to install an HP AdvanceStack 8U/16U SNMP Module. With the module, you can serially connect an ASCII console to the hub to configure, monitor, and troubleshoot the hub.
  • Page 11: Table Of Contents

    Table of Contents Installing the Hub Installation Summary ......Included Parts ......1.
  • Page 12 CompuServe ......2-13 HP FIRST Fax Retrieval Service ....2-14 HP Network Phone-In Support (NPS) .
  • Page 13: Installing The Hub

    Installation Summary 1. Install Add-in Modules (optional) 2. Verify the Hub’s Operation 3. Mount the Hub 4. Complete the Network Connections to the Hub 5. Connect the Hub to an ASCII Console (optional) Installing the Hub...
  • Page 14: Installation Summary

    Installing the Hub This chapter describes how to install the HP AdvanceStack Hub-8U, verify its operation, and connect it to a network, other hubs, computers, and/or other devices. Installation Summary The basic hardware installation procedure for the HP AdvanceStack Hub-8U is as follows: 1.
  • Page 15: Install Add-In Modules (Optional)

    Inspect your installation site and identify whether the hub’s module slots will be accessible. The HP J3133A AdvanceStack 8U/16U SNMP Module enables you to connect a PC to the hub to configure, monitor, and troubleshoot the hub.
  • Page 16 HP J2607A Twisted-Pair Transceiver Module for 10Base-T networks HP J2609A AUI Port Module for connecting a standard IEEE 802.3 external transceiver to the hub The HP AdvanceStack 8U/16U SNMP Module and HP Transceiver Modules and their cabling configurations are described in their accompanying documentation.
  • Page 17: Verify The Hub's Operation

    N o t e If your installation requires a different ac adapter cable than the one supplied with the hub, contact your HP-authorized LAN dealer or your local HP sales office. 2. Plug the ac power cord into an ac power source. When installing the Hub-8U, note that the ac outlet must be installed near the equipment and should be easily accessible.
  • Page 18: Mount The Hub

    A Port LED stays on if link beat has been detected at the port. A Port LED turns off if link beat is not detected. If you have an optional HP AdvanceStack 8U/16U SNMP Module installed, the Port LEDs have additional meanings.
  • Page 19: Marking The Location

    3 inches (7 cm) of space for the ac power cord, the AdvanceStack 8U/16U SNMP module, and a serial connector. Ensure that the HP AdvanceStack hub(s) do not overload the power circuits, wiring, and over-current protection. To determine the...
  • Page 20: Mounting The Hub

    Installing the Hub Mounting the Hub After the screws are in place, follow the steps below for mounting the hub on a wall or under a desk. 1. For a vertical mount (such as a wall), place the bottom of the hub against the screws.
  • Page 21: Complete The Network Connections To The Hub

    Typical hub connections are: Hub-to-device connections. Connecting to network devices such as computers and printers. Hub-to-hub connections. Connecting to another HP AdvanceStack Hub or other Ethernet hub. Hub-to-network backbones. Connecting to a network backbone. This section describes the different ways you can connect your hub to your network.
  • Page 22: Connecting Hubs Together

    Installing the Hub Connecting Hubs Together Twisted-Pair Cascade Connections To expand your network, the hub can be connected to other hubs by using the Media Dependent Interface (MDI) switch. The MDI/MDI-X switch controls how the signals are sent through the twisted-pair cable connected to Port 1.
  • Page 23 ThinLAN Connections With an HP ThinLAN Transceiver Module for 10Base-2 networks, you can connect your hub to a thinLAN network. The following illustration shows a hub with an HP ThinLAN Transceiver Module connected to a ThinLAN backbone.
  • Page 24: Connecting Hubs To Network Backbones

    50-ohm terminator Hub-8U ThinLAN coax connecting the Hub-8U hubs together HP AdvanceStack 10Base-T Hub-24 50-ohm terminator Connecting Hubs to Network Backbones Connecting the Hub-8U to a ThinLAN Backbone The optional ThinLAN Transceiver Module has a BNC 10Base-2 port that can be used to connect your hub to a ThinLAN backbone.
  • Page 25 Connecting the Hub-8U to a Fiber-Optic Backbone With an HP Fiber-Optic Transceiver Module for 10Base-FL networks, you can connect your hub to a fiber-optic backbone. The following illustration shows a hub with an HP Fiber-Optic Transceiver Module connected to a fiber-optic backbone: HP J2606A Fiber-Optic...
  • Page 26: Connect The Hub To An Ascii Console (Optional)

    Installing the Hub 5. Connect the hub to an ASCII console (optional) The optional HP AdvanceStack 8U/16U SNMP Module enables you to configure, monitor, and troubleshoot the hub from an ASCII console. ASCII console 1-14...
  • Page 27: Troubleshooting

    Troubleshooting Approaches Diagnosing with the LEDs Installation Problems Cabling Problems Unusual Network Activity Diagnostic Tests Customer Support Services Replacement Instructions Troubleshooting...
  • Page 28: Troubleshooting Approaches

    Troubleshooting This chapter describes how to diagnose and resolve operating problems with your hub. Additionally, if you have an HP J3133A AdvanceStack 8U/16U SNMP Module installed, you can use ASCII console software for certain diagnostic functions to troubleshoot the hub.
  • Page 29: Diagnosing With The Leds

    During the self-test, all of the LEDs turn on for a short time. If an HP Transceiver module is properly installed, the AUI/Xcvr LED stays lit. If an HP Transceiver module is not installed, the AUI/Xcvr LED turns off. When the self-test completes successfully, the LEDs go into their normal operational states.
  • Page 30: Led Error Indications

    For hub-to-hub connections, set the switch to MDI. For hub-to-PC connections, set the switch to MDI-X. Verify that the HP Transceiver Module is firmly inserted into the AUI/Xcvr slot into the back of the hub. See the documentation accompanying the HP Transceiver module for more troubleshooting information.
  • Page 31 SQE test disabled. For information about the SQE test, see your documentation accompanying your transceiver module. If you have an HP AdvanceStack 8U/16U SNMP Module installed, see the manual for the module. The port has been auto-partitioned because of Slow an excessive collision condition.
  • Page 32: Installation Problems

    Properly connecting cables to the transceiver modules is described in the documentation that accompanies those modules. If you are using the optional HP ThinLAN Transceiver Module, be certain that the thin coax segment attached to the port is properly terminated with a 50-ohm terminator at both ends, as described in the manual accompanying the transceiver module.
  • Page 33: Unusual Network Activity

    Refer to the guide entitled Designing HP AdvanceStack Workgroup Networks for topology configuration guidelines. Contact your HP-authorized LAN dealer or local HP sales office to get a copy of this guide. Unusual Network Activity...
  • Page 34: Diagnostic Tests

    IEEE 802.3 Type 10Base-T standard. To verify that your cable is compatible with this standard, you can use the HP J2263A Cable Test Set. The older HP 28687A Wire Test Instrument can also be used. HP also offers a wire testing service.
  • Page 35: Testing End-To-End Network Communications

    — such that you can verify that the data was correctly transmitted between the devices. For example, if you have two PCs on the network that have HP LAN adapter cards, you can use the “Link Test” option from the card’s test program to verify the entire communication path between the two PCs.
  • Page 36: Replacement Instructions

    The faulty hub should be returned to Hewlett-Packard with the AUI/Xcvr and management slots empty and the cover plates installed. For information about how to remove the modules, see the manuals accompanying the HP Transceiver Module and the HP AdvanceStack 8U/16U SNMP Module. 2-10...
  • Page 37: Customer Support Services

    After you download the file, extract the file (e.g., j3133a /x) The URL address for the World Wide Web is: http://www.hp.com/go/network_city From this web site, you can download files and learn about HP networking products. After you download the file, extract the file (e.g., j3133a /x) 2-11...
  • Page 38: Hewlett-Packard Ftp Library Service

    Troubleshooting Hewlett-Packard FTP Library Service To access the HP FTP Library, follow these steps: 1. Enter the command: ftp ftp-boi.external.hp.com The ftp> prompt appears. 2. At the ftp > prompt, enter: anonymous 3. At the password prompt, enter your internet e-mail address.
  • Page 39: Compuserve

    Troubleshooting CompuServe CompuServe is an electronic information and communication service run by an independent company. The service is typically accessed with a computer and modem and uses standard voice telephone lines for transmitting and receiving data. CompuServe is available 24 hours-a-day, seven days per week.
  • Page 40: Hp First Fax Retrieval Service

    Troubleshooting HP FIRST Fax Retrieval Service HP FIRST is an automated fax retrieval service that is available 24 hours a day, seven days a week. HP FIRST provides information on the following topics: Product information Troubleshooting instructions Technical reviews and articles...
  • Page 41: Hub Reference

    Front of the Hub Back of the Hub Hub Operation Hub Reference...
  • Page 42: Front Of The Hub

    Hub Reference Front of the Hub Hub status LEDs The hub status LEDs indicate whether the hub is functioning properly. For further details on error conditions indicated by the Status LEDs, see chapter 2, “Troubleshooting”. State Meaning of LED Power The hub is receiving power.
  • Page 43: Port Status Leds

    For information about the hub LEDs when a module is installed, see the manual accompanying the module. State Meaning of LED AUI/Xcvr An optional HP Transceiver Module is properly installed in the Port (green) hub’s back panel slot. An HP Transceiver Module is not installed. Slow The HP Transceiver Module port has auto-partitioned.
  • Page 44: Back Of The Hub

    The management slot is used to add an HP J3133A AdvanceStack 8U/16U SNMP Module. For more information, see the “Install Add-in Modules” section in chapter 1. AUI/Xcvr Slot The AUI/Xcvr Slot is used to add an HP Transceiver Module. For more information, see the “Install Add-in Modules” section in chapter 1.
  • Page 45: Hub Operation

    Hub Reference Hub Operation The HP AdvanceStack Hub-8U is a multiport repeater that conforms to the IEEE 802.3 repeater specification. Data signals coming into the hub from any of its ports are automatically regenerated and transmitted to all the other hub network ports. The hub regenerates the data without interpreting the contents, so it can be used in either IEEE 802.3 or Ethernet networks...
  • Page 46: Link Beat

    Hub Reference Link Beat Type 10Base-T devices use a signal called link beat (also called link test pulse). This signal informs the hub of the presence of a device connected to it over twisted-pair cable and of the integrity of the twisted-pair link between them.
  • Page 47: Cables And Connectors

    Recommended Cables Twisted-Pair Cable/Connector Pin-Outs ThinLAN Requirements Cables and Connectors...
  • Page 48: Recommended Cables

    92268B (4 pair, 8 meters) connection using the 92268C (4 pair, 16 meters) MDI/MDI-X switch 92268D (4 pair, 32 meters) 92268N (4 pair, 300 meters) You can contact your HP-authorized dealer or call HP at 1-800-538-8787 to order these parts.
  • Page 49: Twisted-Pair Cable/Connector Pin-Outs

    Cables and Connectors Twisted-Pair Cable/Connector Pin-Outs Twisted-Pair Cable for Hub-to-Computer Network Connection To connect PCs or other network devices to the hub, use a “straight-through” 10Base-T cable. The twisted-pair wires must be twisted through the entire length of the cable. The wiring sequence must conform to AT&T 258A (not USOC).
  • Page 50: Twisted-Pair Cable Pin Assignments

    (receive –) ThinLAN Cable Requirements If you add an HP J2608A ThinLAN Transceiver Module, the thin coaxial cables used with the module must comply with the IEEE 802.3 Type 10Base2 requirements. Some RG-58 A/U or RG-58 C/U cables meet these requirements.
  • Page 51: Specifications

    Physical Electrical Environmental Connectors Electromagnetic Specifications...
  • Page 52 Specifications Physical Width: 21.6 cm (8.5 in) Height: 4.1 cm (1.6 in) Depth: 17.0 cm (6.7 in) Weight: 0.8 kg (1.5 lb) Electrical ac voltage: 100-240 volts Maximum current: 0.7 A max Frequency range: 47/63 Hz Environmental Operating Non-Operating Temperature: 0°C to 55°C -40°C to 70°C (32°F to 131°F)
  • Page 53 Specifications Electromagnetic Emissions FCC part 15 Class A EN 55022 Class A / CISPR-22 Class A VCCI Level I Complies with Canadian EMC Class A requirements Immunity See the Declaration of Conformity for details at the end of the Regulatory Statements. Accoustic Noise Not applicable...
  • Page 55 Safety and Regulatory Statements...
  • Page 56 Safety Information Safety Symbols Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. A WARNING in the manual denotes a hazard that can cause injury or death. WARNING A CAUTION in the manual denotes a hazard that can damage equipment.
  • Page 57 Informations concernant la sécurité Symboles de sécurité Symbole de référence à la documentation. Si le produit est marqué de ce symbole, reportez-vous à la documentation du produit afin d’obtenir des informations plus détaillées. WARNING Dans la documentation, un WARNING indique un danger susceptible d’entraîner des dommages corporels ou la mort.
  • Page 58 Hinweise zur Sicherheit Sicherheitssymbole Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten. WARNING Eine WARNING in der Dokumentation symbolisiert eine Gefahr, die Verletzungen oder sogar Todesfälle verursachen kann.
  • Page 59 Considerazioni sulla sicurezza Simboli di sicurezza Simbolo di riferimento alla documentazione. Se il prodotto è contrassegnato da questo simbolo, fare riferimento alla documentazione sul prodotto per ulteriori informazioni su di esso. WARNING La dicitura WARNING denota un pericolo che può causare lesioni o morte. CAUTION La dicitura CAUTION denota un pericolo che può...
  • Page 60 Consideraciones sobre seguridad Símbolos de seguridad Símbolo de referencia a la documentación. Si el producto va marcado con este símbolo, consultar la documentación del producto a fin de obtener mayor información sobre el producto. WARNING Una WARNING en la documentación señala un riesgo que podría resultar en lesiones o la muerte.
  • Page 61 Safety Information...
  • Page 62 Regulatory Statements FCC Statement (For U.S.A. Only) Federal Communications Commission Radio Frequency Interference Statement Warning: This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause interference to radio communications.
  • Page 63 Declaration of Conformity The following Declaration of Conformity for the HP AdvanceStack Hub-8U complies with ISO/IEC Guide 22 and EN 45014. The declaration identifies the product, the manufacturer’s name and address, and the applicable specifications that are recognized in the European community.
  • Page 65 Index...
  • Page 66 ... 1-2 installing optional modules ... 1-3 obtaining software from ... 2-11 brackets, mounting using to get HP product information ... 2-14 how to order ... 1-8 features ... v bulletin board fiber-optic backbone ... 1-13 obtaining software from ...
  • Page 67 included parts ... 1-2 description ... 3-6 installation problems ... 2-6 list installing ... 1-2 included parts ... 1-2 mounting ... 1-6 operation ... 3-5 replacing ... 2-10 management slot ... 3-4 specifications ... B-2 managing the hub ... 1-14 troubleshooting ...
  • Page 68 network port connections ... 1-9 testing the twisted-pair cables ... 2-8 wall mounting the hub ... 1-7 topology faults ... 2-7 unusual network activity ... 2-7 twisted-pair cable hub-to-computer connection ... A-3 recommended cables ... A-2 pin assignments ... A-4 Regulatory statements ...
  • Page 70 Technical information in this document is subject to change without notice. © Copyright 1996 Hewlett-Packard Company Printed in Singapore 2/96 Manual Part Number J2610-90101 *J2610-90101*...

Table of Contents