Redundant Hot-Plug Fans - HP ProLiant DL380 Generation 4 User Manual

Hp proliant dl380 generation 4 server
Table of Contents

Advertisement

Reach underneath and squeeze the middle of the tape drive blank (1).
2.
Pull the blank out of the bay (2).
3.
Install the tape drive.
4.

Redundant hot-plug fans

NOTE: This procedure shows images of the SCSI model server, but it also applies to the SAS model server.
In the standard configuration, five fans cool the server: fans 2, 4, 5, 6, and 7.
For the redundant configuration, fans 1, 3, and 8 are added to cool the server. This allows the server to
continue operation in non-redundant mode if any one fan fails.
The server supports variable fan speeds to allow the speed of all fans to increase if the temperature in any
area increases. The fans will run at minimum speed until a temperature change requires a fan speed
increase to cool the server.
The server shuts down in the following scenarios:
At POST:
Hardware options installation 50

Advertisement

Table of Contents
loading

Table of Contents