Scsi Ids; Removing A Scsi Hard Drive Blank - HP ProLiant DL380 Generation 4 User Manual

Hp proliant dl380 generation 4 server
Table of Contents

Advertisement

The SCSI ID for each hot-plug hard drive is set automatically to the next sequential ID number in a
series beginning with ID0.
If only one SCSI hard drive is used, install it in the bay with the lowest number.
Hot-plug hard drives must be either Wide Ultra2, Ultra3, or Ultra320 SCSI types. Mixing these types
with other drive standards degrades the overall performance of the drive subsystem.
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.

SCSI IDs

The server supports single- or dual-channel hard drive configurations. The single-channel configuration
(simplex) supports up to six hard drives on one channel. The dual-channel configuration (duplex) supports
two hard drives on one channel (SCSI IDs 0 and 1) and up to four hard drives on the other channel (SCSI
IDs 2 through 5).
The SCSI IDs for both simplex and duplex configurations are illustrated. Always populate hard drive bays
starting with the lowest SCSI ID.

Removing a SCSI hard drive blank

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays
are populated with either a component or a blank.
Hardware options installation 44

Advertisement

Table of Contents
loading

Table of Contents