Conversion To Natural Gas Or To Lpg; Injectors Replacement Of Top Burners - Caple Sense CR1204 Instruction Manual

1000mm range
Table of Contents

Advertisement

Conversion to Natural Gas or to LPG

Injectors replacement of
top burners
Every cooker is provided with a set of
injectors for the various types of gas.
Injectors not supplied can be obtained
from the After-Sales Service.
Select the injectors to be replaced
according to the table at page 21.
The nozzle diameters, expressed in
hundredths of a millimetre, are marked
on the body of each injector.
To replace the injectors proceed as fol-
lows:
– Remove the grids and extract the
burner bodies.
– Using a wrench, substitute the nozzle
injectors "J" (Figs. 3.4a, 3.4b, and
3.4c) with those most suitable for the
kind of gas for which it is to be used
(see "Table for the choice of the injec-
tors").
The burners are constructed in such
a way so as not to require the regu-
lation of the primary air.
DUAL burner
J
Injectors for
outer crowns
Auxiliary and
Semi-rapid
burner
Fig. 3.4a
Triple-ring
burner
Fig. 3.4b
J
Injector for inner crown
J
J
Fig. 3.4c
19