Tree Configuration; Tree Configuration Example - Extron electronics VSW 2VGA A User Manual

2-input, 1-output vga and audio switcher
Hide thumbs Also See for VSW 2VGA A:
Table of Contents

Advertisement

Installation and Operation, cont'd

Tree configuration

In a tree configuration, the output of each VSW 2VGA A
switcher is connected to input 1 or input 2 of the next switcher.
This repetition of one switcher's output to another switcher's
input can be repeated for up to a maximum of 10 switchers in
a daisy chain. The output of the last switcher is connected to a
display.
Source signals are connected to input 1 and input 2 of each VSW
2VGA A switcher at the top of the tree through a VSW I AAP
interface. Select the source by pressing the VSW I AAP's Show
Me button for the corresponding switcher.

Tree configuration example

The following illustration is a simple example of daisy chaining
using a tree configuration.
VSW 2VGA A • Installation and Operation
2-18
Switchers can be daisy chained in this configuration up to
ten levels deep without any signal degradation.
A power supply is required for each switcher in the
chain that has its output connected to input 1 of the next
switcher.
Sources can only be selected and connected to the
switcher through the VSW I AAP interface.
Each VSW I AAP must be configured for the tree
configuration. See
for additional information.
"Using the VSW I AAP"
in this chapter

Advertisement

Table of Contents
loading

Table of Contents