Electrical; Wiring Diagrams - Jet J-7040 Operating Instructions And Parts Manual

10-inch x 16-inch horizontal band saw
Table of Contents

Advertisement

4. Close the blade cover and secure with four knobs.

Electrical

Observe the following when connecting to the power
source. (The cut-off saw wiring diagrams are provided
in Figures 17 and 18.)
WARNING: JET RECOMMENDS THAT ANY WIRING
INVOLVING HARD WIRING OF THE SAW TO A
BRANCH, OR ANY CHANGE OF VOLTAGE SUPPLIED
TO THE MOTOR BE PERFORMED BY A LICENSED
ELECTRICIAN.
1. Make sure the saw is disconnected from the power
Figure 21: Model J-7020 cut-off saw wiring diagram
115 Volt
1
3
2
4
L1
L2
Figure 22: Connection diagram for 1ph motor
220 Volt
1
2
3
4
L1
L2
source, or that the fuses have been removed or break-
ers tripped in the circuit in which the saw will be
connected. Make sure you put a warning placard
on the fuse or circuit breaker to prevent accidental
electrical shock.
2. If you are installing the motor power cord into a re-
ceptacle, make sure to use the appropriate plug.
3. If you are using hard-wired connections to a junc-
tion box, connect the wires in the box, and close
the box.
4. Install the fuses or reset the breaker.
5. The saw is now ready for service.
17