INSTALLATION INSTRUCTIONS

FAST-FILL WATERFALL SPOUT

The Fast-Fill Waterfall Spout will be stubbed as in Figure 2B.
WARNING:
2A
FROM VALVES
Fast-Fill Waterfall Spout
is stubbed out with a 3/4" female
threaded brass fitting.

PLUMBING

1.
After securing bath in place, normal waste and overflow and valves are installed per normal plumbing procedures, in
accordance with all state and local standards.
2.
Install standard 1-1/2" trap to drain and overflow. Before proceeding make final operational check by filling tub with
water to overflow and operate pumps for 5 minutes. Check for leaks carefully both while pump is running and has been
turned off. Allow water to stand in tub for at least 30 minutes before draining. AQUATIC WILL NOT BE RESPONSIBLE
FOR WATER DAMAGE OF ANY KIND IN CONNECTION WITH ONE OF OUR AIR-WHIRLPOOL BATHS. Aquatic
recommends the use of 3/4" valves.
3.
All Millennium Series models are equipped with an integral Fast-Fill Waterfall Spout (unless ordered without this feature).
Purchasing a spout is unnecessary, however, hot and cold water valves are needed. Valves can be mounted where you
choose, however, if installation is to be on tub deck, check the back side of the tub for adequate space for connection
to water lines before drilling or cutting tub.
NOTE: For Rough-in measurements please refer to unit's technical data sheet.
10
DO NOT OVER TIGHTEN! DO NOT USE TEFLON TAPE.
Damage to fitting is not covered under warranty.