17. To verify and record the unit's Ethernet address, type addr
-d and press
The screen display looks similar to this:
monitor:: addr -d
Ethernet address (hex): 00-80-2d-XX-XX-XX
Internet address: <uninitialized>
Subnet mask: 255.255.0.0
Broadcast address: 0.0.0.0
Preferred Load Host address: <any host>
Preferred Dump Host address: 0.0.0.0
Load/Dump Gateway address: 0.0.0.0
Type of IP packet encapsulation: <ethernet>
Load Broadcast: Y
18. Verify that the Remote Access Concentrator is on-line by
entering the net command. The following prompt appears:
Enter Segment to be used [1]:
A "pass" or "fail" message is displayed. If fail is displayed, try
verifying the network from another device.
Once the Remote Access Concentrator is on-line, you can download the
image software to the server (see
and Loading the Image" on page
at the monitor prompt: