Completing The Hot Swap - Nortel 5399 Hardware Installation Manual

Access switch
Hide thumbs Also See for 5399:
Table of Contents

Advertisement

Chapter 4
Troubleshooting Procedures
Nortel Networks 5399 Access Switch Hardware Installation Guide
4-22

Completing the Hot Swap

To complete the hot swap of the Remote Access Concentrator:
1.
Verify that the jumper settings on the replacement module
are the same as the settings on the original module.
2.
Use the procedures outlined in
replacement module into the System 5000 chassis.
3.
Boot the replacement Remote Access Concentrator.
The saved EEPROM information is read by the Remote Access
Concentrator at boot time only in a hot swap situation. The
Remote Access Concentrator compares the "board serial
number" field (in the supervisory module nonvolatile memory)
against its internal serial number. After loading the operational
image, the initialization process sets up the network interface
and then reads the params.n.n.n.n file from the host server, and
places it in local memory. The EEPROM file contents are
decrypted and written to the EEPROM. The buffer containing
the files is then discarded. This process may take several
minutes to complete.
4.
If applicable, obtain a new LAT key and enter it.
Chapter 2
to insert the

Advertisement

Table of Contents
loading