Fader Calibration

After cleaning or replacement, the sensors may get moved, affecting the contour. After any fader service,
perform this procedure to re-calibrate the faders and crossfader.
1. Power off the Sixty-One.
2. Move all faders to the center-most position.
3. Push down both DECK 1 and DECK 2 CUE buttons at the same time.
4. While holding these buttons down, power on the Sixty-One.
5. Immediately after fading up, the CUE lights will flash one time, indicating a successful calibration. If the
CUE lights flash three times, the sensors may have moved too far, or the faders knobs may not have all
been centered, and the faders cannot correctly calibrate.
Problems? Contact Rane Corporation customer service at 425-355-6000 or email us at info@rane.com.