SGM VPL Series User Manual

SGM VPL Series User Manual

Led video pixel linear

Advertisement

Quick Links

USER
MANUAL
LED
VIDEO PIXEL LINEAR
Product Version 1.0 | Document Revision D | Released 2023-01-10
This manual covers installation, use, and maintenance of the SGM LED Video Pixel Linear. A digital version is
available at www.sgmlight.com or upon request via support@sgmlight.com. The information in this docu-
ment is subject to change without notice. SGM and all affiliated companies disclaim liability for any injury,
damage, direct or indirect loss, consequential or economic loss, or any other loss occasioned by the use of,
inability to use, or reliance on the information contained in this manual. The SGM logo, the SGM name, and
all other trademarks in this document pertaining to SGM services or SGM products are trademarks owned
or licensed by SGM, its affiliates, and subsidiaries. This edition applies to firmware version 2.23 or later.
English edition © 2022 SGM Light A/S ® .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VPL Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SGM VPL Series

  • Page 1 The SGM logo, the SGM name, and all other trademarks in this document pertaining to SGM services or SGM products are trademarks owned or licensed by SGM, its affiliates, and subsidiaries.
  • Page 2: Dimensions

    DIMENSIONS 63,29mm 1243,80mm 2,492in 48,969in 1307,09mm 51,460in 623,90mm 63,15mm 2,49in 24,56in 687,05mm 27,05in 63,15mm 313,90mm 12,36in 2,49in 377,05mm 14,84in 1212mm 47,717in 1180mm 46,457in 602,40mm 23,72in 570,40mm 22,46in 297,60mm 11,72in 265,60mm 10,46in 51,58mm 2,031in 38mm 1,496in All dimensions in millimetres and inches. Drawing not to scale Product Version 1.0 | Revision D | Released 2023-01-10...
  • Page 3: Table Of Contents

    6 VPL variants 7 INSTALLATION 7 Identifying power & data 7 Unpacking 7 Application considerations 7 Transport handling 8 Rigging process using SGM brackets 9 Temporary installations 9 Safety wires 10 Frames 11 GROUNDING OF FIXTURES 11 Installing ground wire 12 CONNECTING THE VPL SERIES 12 Permanently Connecting Power &...
  • Page 4: Safety Information

    WARNING! READ THE FOLLOWING SAFETY PRECAUTIONS CAREFULLY BE- FORE UNPACKING, INSTALLING, POWERING OR OPERATING THE DEVICE. SGM fixtures are intended for professional use only. They are not suitable for household use. Les fixtures SGM sont impropre à l’usage domestique. Uniquement à usage professionnel.
  • Page 5: Before Installing This Product

    EXTERNAL CLEANING AND VISUAL INSPECTION OF THE FIXTURE All users of the SGM fixtures should regularly clean those parts of the fixture directly exposed to the elements, such as the external housing and front lenses. Additionally, all owners of the SGM fixtures must periodically check the external housing of the fixture for structural breaks, deterioration, cracked lenses, or loose screws.
  • Page 6: Overview

    OVERVIEW The VPL Series is a group of "Video Pixel Linear" fixtures. Each VPL is an array of LED Quad-Pixel clusters inde- pendently controlled, designed to create powerful pixel mapping and media effects for both indoor and outdoor installations. The fixture is a perfect lighting fixture for linear and radial installations where high-visibility and very flexible setup are essential.
  • Page 7: Installation

    INSTALLATION IDENTIFYING POWER & DATA The VP cable with the male connector is the flexible cable which extends from the power supply, while the female VP data connector is mounted directly into the power supply (see figure 1). Male VP Power + Data connector Power supply Female VP Power + Data connector...
  • Page 8: Rigging Process Using Sgm Brackets

    RIGGING PROCESS USING SGM BRACKETS SGM offers three brackets for installation of VPLs: The touring bracket for temporary setups and single or dual bracket for permanent installations. The VPL Touring Bracket (P/N: 83060633) (see figure 2) is perfect for temporary installations. It has a snap-on sliding...
  • Page 9: Temporary Installations

    A VPL Single Touring bracket can carry a one bracket SGM VPL 1220-20 if it is placed no more than 300 mm away from either end of a VPL. (see figure 5). two brackets Figure 5: Bracket guide-line, if the bracket is closer to than 300mm to the edge, two brackets are advised.
  • Page 10: Frames

    VPL 305-20 cannot bend a full 90 degree due to the compactness of the fixture's cable. Make sure the installa- tion is rigid so that the fixtures cannot move and cause extensive wear on the cables. For further information or suggestions about the VLP and their installation, please contact your local SGM distributor or SGM support at support@sgmlight.com Figure 8: Orientations of a corner lying flat or sideways.
  • Page 11: Grounding Of Fixtures

    GROUNDING OF FIXTURES When installing VPLs on the exterior of high buildings it is always recommended to ground the individual fixtures to the building to minimize the risk of failure due to lightning strikes. Make sure to check the local building code for possible directives or laws regarding lightning prevention.
  • Page 12: Connecting The Vpl Series

    PERMANENTLY CONNECTING POWER & DATA The VPL Series can operate on any 200–240 V, 50/60 Hz AC mains power supply. Power is connects to the fixture via a Power+Data joiner or inserter (not included) (see figure 11 for connection diagram).
  • Page 13: Connect To Ac Power

    CONNECT TO AC POWER Connect the fixture to AC power using a SGM Power + Data joiner (not included) or similar. To ensure the correct ingress protection (IP-rating), always use the SGM VP cables, and waterproof RJ-45 kit (see figure 13) Order number: (83062057).
  • Page 14: Cable Lengths

    CABLE LENGTHS SGM offers 3 lengths of extension cable; 1m, 2.5m and 5m. However, it is possible to purchase a Custom Extension Cable Kit in either 1m or 10m (1m: P/N 83062054, 10m P/N 83062055), and the Crimping tool for VP connectors(P/N 83062301), to make cables of any length.
  • Page 15: Vp Connector

    VP CONNECTOR The VPL Series has a female multi-core 8 pin cable located in the first end of the VPL, and a male multicore 8 pin connector in the last end of the VPL. The 8 pins are divided by 1xShield, 3xPower, 4xSignal (see figure 18).
  • Page 16 Step 1 Step 2 Draw the linear path guide-lines for the VPLs and Attach a second bracket to the VPL at the end with the install the first bracket oblong hole, by clicking it into place. Step 3 Step 4 Click the VPL into the installed bracket.
  • Page 17: Replacing A Fixture / De-Mounting

    REPLACING A FIXTURE / DE-MOUNTING Step 1 Step 2 Loosen the bolts while holding the profile and Remove the VPL by carefully twisting the profile begin to loosen the single hole side bracket. off the bracket. You can get a grip through the hole near the connector.
  • Page 18: Replacing

    VPL NETWORKING GUIDE The VPL is intended to be set up for use prior to programming using the SGM Network Admin software available for PC. Using the Admin software, the VPL system is designed for easy installation and patching. For detailed instruc- tions and guidance on setup and configuration, please refer to the SGM Network Admin.
  • Page 19: Network Setup

    RGB pixel style control. If possible, SGM advises keeping VPL networks separated from general building networks or using VLAN’s to avoid excess network traffic. Networked data traffic for pixel control is not suitable for typical TCP/IP network settings and often is not able to be managed effectively with general IT personnel.
  • Page 20: Universal Datagram Packet (Udp)

    SGM recommends to enable IP based flow control if possible. NETWORK SIZE SGM does not specify a preferred topology for a network. However, in large networks, the introduction of routers and extra switches can introduce data delays on the signal path. It is recommended to incorporate a minimum of devices between the lighting data controller and the VPL installation.
  • Page 21: Lenses And Lens Accessories

    LENSES AND LENS ACCESSORIES The direct view of the VPLs can be modified with snap-on lenses. VPL Opal Lens Smoked frosted Lens VPL Rounded Smoked Opal lens VPL Opal/Black Lens Smoked clear Lens Product Version 1.0 | Revision D | Released 2023-01-10...
  • Page 22: Removing A Lens

    REMOVING A LENS The best way to remove a VPL lens is to open the hooks at the profile and lift the lens up. We strong- ly recommend not to use any metal tools in the process as these can damage both the VPL lens, the VPL aluminium profile, the optical silicone and, in worst case, the LEDs, which will result in a reduced Ingress Protection.
  • Page 23: Factory Default With Magnet

    The only maintenance related to the VPLs is periodical exterior cleaning and occasional update of the firmware. UPGRADING THE FIRMWARE The installation of the upgrade is done through the SGM Network Admin tool. To execute the installation please see the SGM Network Admin manual.
  • Page 24: Fixtures And Accessories

    PLEASE NOTE! THE LIST BELOW IS SUBJECT TO CHANGE WITHOUT NOTICE. The VPL Series can be used with a variety of accessories. Contact your local SGM dealer to get the latest pricing and news about available accessories. Please note: the products listed below are subject to change without notice.
  • Page 25: Support Hotline

    SUPPORT HOTLINE SGM offers 24/7 technical support. Worldwide: +45 3840 3840 US: +1 407-242-6217 support@sgmlight.com APPROVALS AND CERTIFICATIONS Conforms to ..............2014/35/EU: Low Voltage Directive Conforms to .
  • Page 26: User Notes

    USER NOTES Product Version 1.0 | Revision D | Released 2023-01-10...
  • Page 27 SGM LIGHT A/S Sommervej 23 8210 Aarhus V Denmark Tel: +45 70 20 74 00 info@sgmlight.com www.sgmlight.com Product Version 1.0 | Revision A | Released 2023-01-10...

This manual is also suitable for:

Vpl 1220-20Vpl 610-20Vpl 305-20