Automatic gas water boiler

Advertisement

BURNER REMOVAL: The burner can be removed with the unit standing in operating
position. Turn off the gas flow to the unit. Allow the burner to cool off. Remove the wing
nut holding the burner to the frame. Pull down the free burner end, enough to clear the
threaded stud and pull the burner horizontally away from the manifold orifice. The
burner can now be cleaned or replaced. To reinstall reverse the above procedure.
BURNER MAINTENANCE: The burner should be cleaned both inside the venturi
portion and on the outside using a soft bristle brush. The burner must be replaced into
the same position as prior to removal. Once a year a qualified service agency should
be contacted to inspect the appliance for safe and proper operation.