  • Page 1 ME10E-N ME15E-N CME10E-N CME15E-N 18 Gauge Type 304L Stainless Steel construction to resist corrosion. Solid State water level control for automatic refill CONTENTS Specifications Start up Instructions Trouble Shooting Guide Parts List Wiring Diagram Operation Manual NP57A 10-2006...
  • Page 2 VENT OPENING POWER SUPPLY BOX POWER ON LIGHT HEATER ON ME10E-N LIGHT CAUTION POWER HOT SURFACES SWITCH TEMPERATURE CONTROL "A" TEMPERATURE CONTROL SIDE ACCESS DOOR OVERFLOW (SLIDES UP) THERMOMETER WATER INLET 14.0 16.0 NOTE: 1. FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS.
  • Page 3 Every Cecilware urn body is covered for three years. This warranty covers the stainless steel body and stainless steel liners only. Portable equipment such as Electric Fryers, Food Warmers, Electric Stoves, Dispensers, Plug-In Urns, Coffee Brewers and Warmers must be returned to the factory or brought to an authorized service station for repair.
  • Page 4: Electrical/Water Hook-Up

    ELECTRICAL HOOK-UP PROCEDURES: FOR QUALIFIED SERVICE PERSONNEL ONLY NOTE: Always check the rating plate of the unit for proper voltage and current requirements. 1. 120V water boilers are provided with 120V/15A grounding plug. Units must have a separate 120V/15A outlet. 2.
  • Page 5 COUPLING COMPONENT TESTS A) Thermostat Adjustments: The Thermostat is factory set for proper dispense temperature of 190° F - CCW - DECREASES with the control shaft set to the maximum clockwise position. If field TEMPERATURE adjustments are needed proceed as follows: To DECREASE temperature, turn the control shaft slightly in the COUNTERCLOCKWISE direction.
  • Page 7 ELECTRICAL DIAGRAM ME10E-N, ME15E-N 120 VOLTS WATER LEVEL CONTROL WATER INLET VALVE 1 FILL 2 AC-1L 3 AC-2N WATER LEVEL 4 L-LEVEL PROBES 5 H-LEVEL 6 COMMON WATER HEATER LIGHT HEATER THERMOSTAT HI-LIMIT SWITCH ON-OFF G199A (1.8 KW) POWER LIGHT...
  • Page 8 ELECTRICAL DIAGRAM ME10E-N, ME15E-N 120/ 240 VOLTS WATER LEVEL CONTROL WATER INLET VALVE 1 FILL 2 AC-1L 3 AC-2N WATER LEVEL 4 L-LEVEL PROBES 5 H-LEVEL 6 COMMON WATER HEATER LIGHT THERMOSTAT HI-LIMIT SWITCH ON-OFF CONTACTOR (SEE HEATERS HOOK-UP SHEET 4)
  • Page 9 ELECTRICAL DIAGRAM ME10E-N, ME15E-N 240 VOLTS WATER LEVEL CONTROL WATER INLET VALVE 1 FILL 2 AC-1L 3 AC-2N WATER LEVEL 4 L-LEVEL PROBES 5 H-LEVEL 6 COMMON WATER HEATER LIGHT THERMOSTAT HI-LIMIT SWITCH ON-OFF CONTACTOR (SEE HEATERS HOOK-UP SHEET 4)
  • Page 10 ELECTRICAL DIAGRAM ME10E-N, ME15E-N 240 VOLTS HEATERS HOOK-UP TERMINAL CONTACTOR BLOCK 1 PHASE 240 VOLTS G197A (2 x 3.5 KW) TOTAL: 7 KW TERMINAL CONTACTOR BLOCK 3 PHASE 240 VOLTS G197A (3 x 3.5 KW ) SHEET 4 of 4 TOTAL: 10.5 KW...