Cecilware ME-10G Operation Manual page 7

Automatic gas water boiler

Advertisement

RELIGHTING: Shut off all gas and wait approximately 3 minutes before relighting the
pilot.
SHUTTING DOWN: For temporary shut down, turn the thermostat to lowest or OFF
position; then turn gas cock dial to PILOT position. To shut boiler down completely,
partially depress and turn gas cock dial to OFF position.
MAINTENACE OR REPAIR: The owner should contact either the manufacturer or an
approved local service company for maintenance or repair of the unit.
CLEANING: The outside of the unit should be cleaned on a regular basis using a
soap solution and a soft cloth or sponge. Abrasive cleaners are not recommended.
For cleaning the burner see section on removal and" cleaning.
FOR QUALIFIED SERVICE PERSONNEL ONLY
THERMOSTAT CALIBRATION: Turn the thermostat knob to "10" and remove knob
without moving the thermostat shaft. Place narrow bladed screw driver (1/8") into the
hollow thermostat shaft and engage center adjustment screw. When thermometer
reading approaches 198F slowly turn the adjustment screw clockwise until the burner
goes out. Turning the screw counter-clockwise will increase the temperature.
SAFETY PILOT: Remove pilot adjustment cap on the gas valve and turn adjustment
screw to provide properly sized flame (3/4 inch long). Replace the cap.
BURNER: Burners are factory set for maximum performance. Should further
adjustment be required loosen slotted hex screw on side of venturi and rotate air
shutter until flame with soft blue inner cone is obtained.
7