Cecilware ME10-GN Operation Manual

Automatic gas water boiler

Advertisement

Quick Links

AUTOMATIC GAS WATER BOILER
ME10-GN ME15-GN
18 Gauge Type 304L
Stainless Steel
construction to resist
corrosion.
Solid State water level
control for automatic
refill
CONTENTS
Specifications
Start up Instructions
Trouble Shooting Guide
Parts List
Wiring Diagram
Operation Manual
NQ24A 12-2006

Advertisement

Table of Contents
loading

Summary of Contents for Cecilware ME10-GN

  • Page 1 AUTOMATIC GAS WATER BOILER ME10-GN ME15-GN 18 Gauge Type 304L Stainless Steel construction to resist corrosion. Solid State water level control for automatic refill CONTENTS Specifications Start up Instructions Trouble Shooting Guide Parts List Wiring Diagram Operation Manual NQ24A 12-2006...
  • Page 2: General Specifications

    "B" "A" OVERFLOW THERMOMETER 14.0 GENERAL SPECIFICATIONS GAS SPECIFICATIONS MODEL NO. ME10-GN ME15-GN ELECTRICAL SPECIFICATIONS NOTE: UNIT IS SUPPLIED WITH A GROUNDED 120V-15A LINE CORD AND PLUG (NEMA 5-15P). POWER SWITCH ME10-GN CAUTION HOT SURFACES TEMPERATURE CONTROL TEMPERATURE CONTROL NP87A NATURAL GAS BTU/ HR @ 3.5"...
  • Page 3: Safety Precautions

    Retain this manual for future reference. UNPACKING INSTRUCTION: Carefully unpack the water boiler and inspect immediately for shipping damages. Your automatic water boiler was shipped in a carton designed to give maximum protection in normal handling. It was thoroughly inspected before leaving the factory and the carrier accepted and signed for it.
  • Page 4 Carefully right the unit and install in its permanent location, being sure to leave at least 6” on the right side of the water boiler for access to the control box. Level the unit by adjusting the bottom pad of the legs. Place the vent cap into the recess in the top of the unit.
  • Page 5 SHUTTING DOWN: For temporary shut down, turn the thermostat to lowest or OFF position, then turn gas cock dial to PILOT position. To shut boiler down completely, partially depress and turn gas cock dial to OFF position. MAINTENANCE OR REPAIR: The owner should contact the manufacturer or an approved local service company for maintenance or repair of the unit.
  • Page 6: Burner Removal

    BURNER: The burner is factory set for maximum performance. Should further adjustments be required loosen slotted hex screw on side of venturi and rotate air shutter until flame with soft blue inner core is obtained. BURNER REMOVAL: The burner can be removed with the unit standing in operating position. Turn off the gas flow to the unit.
  • Page 9 SCREW, 10-24 X 1/2" PAN HEAD, PHILLIPS P528A WASHER P810A WING NUT, 10-24, SST P813A WASHER, S.S. (0.382 ID x 0.642 OD x .028 THK) Q102A COVER U019A VENT CAP DRAIN U160A GAUGE SHIELD MOUNTING BRACKET PARTS LIST ME10-GN ME15-GN...
  • Page 10: Component Tests

    COMPONENT TESTS A) Thermostat Adjustments: The Thermostat is factory set for proper dispense temperature of 200°F ± 3°F with the control knob set to the maximum clockwise position. If field adjustments are needed proceed as follows: To DECREASE temperature, turn the control knob slightly counter-clockwise. For qualified technicians ONLY: To INCREASE the water temperature - With the Thermostat Knob to its maximum clockwise position, remove the knob and locate the slotted adjustment screw...
  • Page 11 ELECTRICAL DIAGRAM ME10G-N, ME15G-N WATER INLET VALVE POWER LIGHT CECILWARE CORPORATION 120/ 240 VOLTS WATER LEVEL CONTROL WATER LEVEL PROBES WATER 1 FILL 2 AC-1L 3 AC-2N 4 L-LEVEL 5 H-LEVEL 6 COMMON POWER SWITCH...