inlet valve rod (53). Place the vent cap (50) into the recess in the top of the unit. Mount
the faucet assembly (56) onto the shank (18).
10 AND 15 GALLON GAS WATER BOILERS
Model no.
ME-10G
ME-15G
INSTALLATION AND OPERATING INSTRUCTION:
PRE-INSTALLATION INSTRUCTIONS: The installation of your water boiler must be
made by a licensed plumber and the installation must conform with State and Local
Codes or in absence of Local Codes, with the National Fuel Gas Code ANSI Z223.1 a
latest version.
AIR SUPPLY AND VENTILATION: Adequate ventilation and air supply must be
provided in order for the water boiler to operate properly and efficiently. The area in
front of and above the unit must be clear to avoid any obstruction of flow of combustion
and ventilation air. DO NOT under
any circumstances, connect the water boiler flue directly to 3 building exhaust system
or place the flue outlet directly into the plenum of the exhaust hood as it will adversely
affect the gas combustion of the water boiler.
Water
Capacity
(Gallons)
10.0
15.0
Dimensions
(inch)
A
B
28
31
32
35
3
Shipping Wt.
(Ib.)
50.0
55.0