Chapter 10 - Serial Programming Commands; Conventions; Menu Command Syntax - Hand Held Products 2020 User Manual

Cordless system
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

10
Serial Programming Commands
The serial programming commands can be used in place of the programming
barcodes. Both the serial commands and the programming barcodes will
program the 2020. For complete descriptions and examples of each serial
programming command, refer to the corresponding programming barcode in this
manual.
The device must be set to an RS-232 interface (see
commands can be sent via a PC com port using terminal emulation software.

Conventions

The following conventions are used for menu and query command descriptions:
parameter A label representing the actual value you should send as part of a
command.
[ option ] An optional part of a command.
{Data}
Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.

Menu Command Syntax

Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix [:Name:] Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] [...]
Storage
Prefix
Three ASCII characters: SYN M CR (ASCII 22,77,13).
:Name:
To send information to the image scanner (with the base connect-
ed to host): :3820: The default factory setting for a 3820 image
scanner is 3820. This setting is changed by using the BT_NAM
command, which accepts alphanumeric values. If the name is not
known, a wildcard (*) can be used :*:.
Note: Since the base stores all work group settings and transfers to them to the
image scanner once they are linked, changes are typically done to the
base and not to the image scanner.
Tag
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS-232 configuration settings
are identified with a Tag of 232.
SubTag
A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS-232 baud rate is BAD.
2020/3820 User's Guide
page
1-21). The following
10 - 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

3820

Table of Contents