5.
Ensure that the DVSe is not currently recording or archiving.
Follow the steps below to Upgrade the DVSe:
Step 1. Launch the Browser software (Microsoft Internet Explorer 5.5 or
later).
Step 2. Enter the IP address of the DVSe in the address field of the Browser
followed by /upgrade.ssi and press enter. For example if the IP
address is 3.18.173.71 type 3.18.173.71/upgrade.ssi.
Step 3. The Enter Network Password window should appear. Enter the
correct Username and Password in their respective fields. (The
default username is admin and the password is admin. It is
recommended that the defaults be changed ASAP). Click the OK
button. The DVSe upgrade page should appear.
Step 4. Navigate to the upgrade file using the Browse button or type in the
correct path and filename. Click on the Send File button.
Step 5. Click on the Confirm Button. A progress bar will appear. PLEASE
WAIT FOR THE PROGRESS BAR TO FINISH, THEN WAIT FOR
CONFIRMATION!
Step 6. Click on the Reboot button to restart the unit for changes to take
effect. If unsuccessful, download the flash file again and retry the
steps 1-6.
Kalatel DVSe
18
0150-0178F