Established Event; Failed Event - Panasonic Selection 470 Programmer's Manual

Digital business system
Table of Contents

Advertisement

Section 470 - TSAPI Programmer's Guide

Established Event

Function: CSTAEstablishedEvent
Direction: C ← S
Functional Description:
The Established Event Report is sent as follows:
• When a call is delivered to a DBS extension and the party has answered the call (CSTA
Service Parameters:

Failed Event

Function: CSTAFailedEvent
Direction: C ← S
Functional Description:
DBS-92-470
The Established Event Report indicates that the DBS detects that a device answers or con-
nects to a call.
Answer Call request, picked up handset or pressed the on/off key).
monitorCrossRefID
establishedConnection
answeringDevice
callingDevice
calledDevice
lastRedirectionDevice
localConnectionInfo
cause
The Failed Event Report indicates that a call cannot be completed or the monitored device
is the last remaining party in the call (i.e., listening to internal busy tone).
Issued April 2000
[mandatory] contains the handle to the monitor request for
which this event is reported.
[mandatory] specifies the endpoint which joined the call.
[mandatory] specifies the device which joined the call.
[mandatory] specifies the calling device. The following rules
apply:
• For internal calls originated at a DBS station - the station's
extension is specified.
• For incoming calls over a trunk the trunk number is speci-
fied.
[optional - partially supported] specifies the originally called
device.
[optional - not supported] specifies the previously alerted
device in case where the call was redirected or diverted to the
answeringDevice.
[optional - not supported] specifies the connection state of the
monitored device for this call.
[optional - not supported] specifies the reason for this event.
31