Label Gone Timeout

This feature sets the time after the last label segment is seen before the scanner prepares for a
new label.
START / END
Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To
configure this feature, scan the "START/END" barcode above to place the unit in Programming Mode, then the "Set Linear Label
Gone Timeout," followed by the three digits (zero padded) from the Alphanumeric table in
senting the desired time value. Exit programming mode by scanning the "START/END" barcode again.

Productivity Index Reporting (PIR)

When PIR is enabled, label quality data is appended to decoded data before being presented to
the POS. The PIR feature allows the scanner to provide information to an external computer,
indicating how easy the label was to read.
DEFAULT
10
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 320 milliseconds (032)
This value-added feature is a factory-programmed
option. Contact your dealer for information about
upgrading your system to include this advanced
capability.
NOTE
PROGRAMMING BARCODES
Disable
Appendix C, Alpha-Numeric Pad
Set Linear Label Gone Timeout
START / END