Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure
Flat-blade screwdriver
Phillips head screwdriver
Drill
Level
6" socket extension
Parts supplied
Vent grille
Grease filter
Grill cartridge
Grease container(s)
Parts needed
A UL listed or CSA approved strain relief for ⁷⁄₈" (2.2 cm)
knockout.
A UL listed or CSA approved conduit connector for
¹⁄₂" (1.3 cm) trade-size metal-clad conduit
UL listed wire connectors
Metal ducting
Jenn-Air wall cap
Jenn-Air
®
6" (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
®
Jenn-Air
3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the "Assistance or Service" section of the Use
and Care Guide.
Vent clamps
Check local codes. Check existing electrical supply. See
"Electrical Requirements" section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. When
installing cooktop, use minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
2

INSTALLATION REQUIREMENTS

Marker or pencil
Pliers
¼" drill bit
Jigsaw
Ratchet with ³⁄₈"socket
Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are minimum
clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See "Electrical
Requirements" section.
If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
IMPORTANT: An under-counter built-in oven cannot be installed
under this product.
Product Dimensions
30" (76.2 cm) Cooktop
B
A
F
A. Tie down bolt (on each side of cookop)
B. 30" (76.2 cm)
C. 21³⁄₄" (55.3 cm)
D. Grease containers
E. Wiring box cover
F. Blower
B
A*
C
D**
A. 6¹⁄₄" (15.9 cm)
B. 3¹⁄₂" (8.9 cm)
C. Grease containers
D. 2" (5.1 cm)
*A minimum clearance of 6¹⁄₄" (15.9 cm) is recommended for
removal of the grease containers. Installed dimension for the
grease containers is 5¹⁄₂" (14.0 cm).
**A minimum clearance of 2" (5.1 cm) is recommended between
the motor/blower and cabinet for proper cooling.
C
D
E
G
C
H
F
E
E. 13³⁄₄" (34.9 cm)
F. 11¹³⁄₁₆" (30.0 cm)
G. 4" (10.2 cm)
H. 13¹³⁄₁₆" (35.1 cm)