Jenn-Air W10298937A Installation Instructions Manual
Jenn-Air W10298937A Installation Instructions Manual

Jenn-Air W10298937A Installation Instructions Manual

30" (76.2 cm) and 45" (114.3 cm) electric downdraft cooktop
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

30" (76.2 CM) AND 45" (114.3 CM) ELECTRIC
DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION DE LA TABLE DE
CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE
COOKTOP SAFETY .................................................................................... 1
INSTALLATION REQUIREMENTS ............................................................ 2
Tools and Parts ........................................................................................ 2
Location Requirements............................................................................ 2
Venting Requirements ............................................................................. 4
Venting Methods...................................................................................... 5
Electrical Requirements .......................................................................... 7
INSTALLATION INSTRUCTIONS .............................................................. 8
Prepare Cooktop...................................................................................... 8
Rotate Blower - Optional ......................................................................... 9
Install Cooktop ....................................................................................... 10
Make Electrical Connection................................................................... 10
Complete Installation ............................................................................. 11
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10298937A
30" (76,2 CM) ET 45" (114,3 CM)
Table of Contents/Table des matières

COOKTOP SAFETY

Your safety and the safety of others are very important.
DANGER
SÉCURITÉ DE LA TABLE DE CUISSON ...........................................13
EXIGENCES D'INSTALLATION..........................................................13
Outillage et pièces ............................................................................13
Exigences d'emplacement ...............................................................13
Exigences concernant l'évacuation .................................................16
Méthodes d'évacuation....................................................................17
Spécifications électriques ................................................................19
INSTRUCTIONS D'INSTALLATION ...................................................20
Préparation de la table de cuisson...................................................20
Rotation du ventilateur - Facultative ................................................20
Installation de la table de cuisson ....................................................21
Raccordement électrique .................................................................21
Achever l'installation.........................................................................23
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W10298937A and is the answer not in the manual?

Questions and answers

Summary of Contents for Jenn-Air W10298937A

  • Page 1: Table Of Contents

    All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. IMPORTANT: Save for local electrical inspector's use. IMPORTANT : À conserver pour consultation par l'inspecteur local des installations électriques. W10298937A...
  • Page 2: Installation Requirements

    B. 30" (76.2 cm) UL listed wire connectors C. 21³⁄₄" (55.3 cm) D. Grease containers Metal ducting E. Wiring box cover Jenn-Air wall cap F. Blower Jenn-Air ® 6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406 ®...
  • Page 3 45" (114.3 cm) Cooktop Cabinet Dimensions A. Tie down bolt (on each side of cookop) B. 45" (114.3 cm) C. 21³⁄₄" (55.3 cm) D. Grease containers E. Wiring box cover F. Blower A. 30" (76.2 cm) on 30" (76.2 cm) models 45"...
  • Page 4: Venting Requirements

    Where possible, a 6" (15.2 cm) clearance is recommended for motor blower service. A minimum clearance of 1" (2.5 cm) is Use a Jenn-Air ® vent cap. recommended to the sidewalls and a ³⁄₄" (1.9 cm) clearance is Vent system must terminate to the outside.
  • Page 5: Venting Methods

    6" (15.2 cm) or 3¹⁄₄" x 10" (8.3 x 25.4 cm) fittings. Avoid forming handmade crimps. Handmade crimps may restrict airflow. Use a Jenn-Air ® vent cap for proper performance. If an alternate wall or roof cap is used, be certain the cap size is not reduced and that it has a backdraft damper.
  • Page 6 Concrete Slab Installations - Calculating Vent System Length Exhaust Through Window Well To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece 6" (15.2 cm) Round 45°...
  • Page 7: Electrical Requirements

    Example vent system 7. Reattach the four acorn nuts to secure the blower motor assembly back to the blower exhaust scroll. wall cap 90˚ elbow 6 ft (1.8 m) 2 ft (0.6 m) 1- 90° elbow = 5 ft (1.5 m) 8 ft (2.4 m) straight = 8 ft (2.4 m) 1 - wall cap...
  • Page 8: Installation Instructions

    Make sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, INSTALLATION INSTRUCTIONS ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances. Prepare Cooktop A copy of the above code standards can be obtained from: National Fire Protection Association...
  • Page 9: Rotate Blower - Optional

    Rotate Blower - Optional IMPORTANT: The following additional steps must be performed if To rotate blower motor: the product is being installed in peninsula or island cabinetry. 1. Using a ratchet with a ³⁄₈" socket and supporting the motor with one hand, remove the four machine nuts that attach the The blower exhaust scroll is shipped from the factory set to blower motor to the exhaust scroll.
  • Page 10: Install Cooktop

    Electrical Connection Options Install Cooktop If your home has: And you will be Go to Section: 1. Using 2 or more people, place cooktop right side up into the connecting to: cutout. NOTE: Make sure that the front edge of the cooktop is parallel 4-wire A fused 4-Wire Cable from...
  • Page 11: Complete Installation

    3-Wire Cable from Home Power Supply to 4-Wire Cable Complete Installation to Cooktop - U.S. only 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. IMPORTANT: Use the 3-wire cable from power supply where local codes permit connecting the frame-ground conductor to the 2.
  • Page 12 Notes...
  • Page 13: Sécurité De La Table De Cuisson

    Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous. Clapet de bouche de décharge murale à surface arrondie de 3¼" x 10" (8,3 x 25,4 cm) de Jenn-Air ® Outils nécessaires Commander la pièce numéro A403 Mètre-ruban...
  • Page 14 Table de cuisson de 45" (114,3 cm) Dimensions du produit Table de cuisson de 30" (76,2 cm) A. Boulon de fixation (de chaque côté de la table de cuisson) A. Boulon de fixation (de chaque côté B. 45" (114,3 cm) de la table de cuisson) C.
  • Page 15 Lorsque c'est possible, un dégagement de 6" (15,2 cm) est Dimensions du placard recommandé pour pouvoir accéder au ventilateur du moteur en cas de réparation. On recommande un dégagement minimal de 1" (2,5 cm) jusqu'aux parois latérales et un dégagement de ³⁄₄" (1,9 cm) jusqu'à la paroi arrière. Un dégagement minimum de 2"...
  • Page 16: Exigences Concernant L'évacuation

    Ne pas installer 2 coudes ensemble. dans un autre espace fermé. Ne pas utiliser plus de trois coudes à 90°. Utiliser un clapet de conduit Jenn-Air ® Si l'on utilise un coude, on doit le placer le plus loin possible Le système doit décharger l'air à...
  • Page 17: Méthodes D'évacuation

    Méthodes d'évacuation Les méthodes d'évacuation standard illustrées correspondent à Installations sur dalle de béton - une table de cuisson avec aspiration par le bas montée sur Évacuation par un puits de fenêtre comptoir. L'évacuation de la table de cuisson peut se faire par le mur ou le plancher.
  • Page 18 Exemple de circuit d'évacuation Calcul de la longueur effective du circuit d'évacuation bouche de décharge murale Pour calculer la longueur effective du circuit d’évacuation coude à 90˚ nécessaire, additionner les longueurs équivalentes (pieds/mètres) 6 pi (1,8 m) de tous les composants utilisés dans le système. Composant Conduit de diamètre de 6"...
  • Page 19: Spécifications Électriques

    Revisser les quatre écrous borgnes pour fixer le moteur du S’assurer que la connexion électrique et le calibre des fils sont ventilateur à la volute d’évacuation du ventilateur. appropriés et conformes au National Electrical Code, à la norme ANSI/NFPA 70 – dernière édition, ou à la norme CSA C22.1-94, au Code canadien de l’électricité, Partie 1 et C22.2 N°...
  • Page 20: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION Préparation de la table de cuisson Rotation du ventilateur - Facultative Déterminer l’emplacement final de la table de cuisson. IMPORTANT : Les étapes supplémentaires suivantes doit être exécutées si le produit est installé dans une configuration d'ébénisterie en péninsule ou en îlot. AVERTISSEMENT La volute d'évacuation est montée à...
  • Page 21: Installation De La Table De Cuisson

    3. Resserrer chaque écrou à l'aide de la douille de ³⁄₈" et de la clé à cliquet. Installation de la table de cuisson 4. Réinstaller le filtre à graisse et la grille de ventilation. 1. À l'aide d'au moins 2 personnes, placer la table de cuisson dans l'ouverture, côté...
  • Page 22 Voir le tableau “Options de raccordement électrique” pour 4. Connecter le conducteur de terre vert (ou nu) du câble de la terminer l’installation correspondant à votre type de raccordement table de cuisson au conducteur de terre vert (ou nu) (dans le électrique.
  • Page 23: Achever L'installation

    Achever l'installation 1. Vérifier que toutes les pièces sont maintenant installées. S'il 6. Reconnecter la source de courant électrique. reste une pièce, passer en revue les différentes étapes pour 7. Utiliser la carte de test du flux d'air fournie avec la table de découvrir laquelle aurait été...
  • Page 24 All rights reserved. ®Registered Trademark/™Trademark of Jenn-Air, U.S.A. Used under license by Maytag Limited in Canada. Printed in U.S.A. Tous droits réservés. ®Marque déposée/™Marque de commerce de Jenn-Air, U.S.A. Emploi sous licence par Maytag Limited au Canada. Imprimé aux É.-U.

Table of Contents