3
Adjust the level of offset/vertical magnification as needed.
Offset Setting
Unit
Select [ADF (front)] or [ADF (back)] as the
target for offset adjustment.
Main
Adjusts the horizontal (width) offset.
The value can range from -2 to +2 mm (in
increments of 0.5).
Sub
Adjusts the vertical (length) offset from the top
of the page.
The value can range from -2 to +2 mm (in
increments of 0.5).
End of page
Adjusts the vertical (length) offset from the
bottom of the page.
The value can range from -2 to +2 mm (in
increments of 0.5).
Vertical
magnification
Adjustment
Unit
The target for vertical magnification
adjustment is fixed to [ADF].
Vertical
Adjusts the vertical (length) magnification.
magnification
The value can range from -3.1 to +3.1% (in
Adjustment (length)
increments of 0.1).
Description