(2) For PCL Option
The PCL Control Program (2) must be written into the 4 MB onboard, which is assigned as ROM
Code (B). The PCL Control Program (3) and PCL Font data (4) are written into the 8 MB in the
SLOT 1. The Firmware (3) and (4) are assigned as ROM Code (C).
When using 8 MB Flash Memory Card, the 8 MB Program (C) can be written onto one card.
When using 4 MB Flash Memory Card, the 8 MB program (C) must be divided onto 2 cards, one 4
MB card for the PCL Control Program (3) and one 4 MB card for the PCL Font data (4).
(3) For PS Option
The PS Control Program must be written into the 4 MB onboard, which is assigned as ROM Code
(D). The PS Control Program (6) and (7) are written into the 8 MB in the SLOT 1.
Both Firmwares (6) and (7) are assigned as ROM Code (E).
When using 4 MB Flash Memory Card, the 8 MB program (E) must be divided onto 2 cards, one 4
MB card for the PS Control Program (6) and one 4 MB card for the PS Control Program (7).
C. SPC PC Board Firmware
The 512 KB Program Memory (F-ROM) is integrated on the SPC PCB. The Programs for Scanner
Control and Printer Control are saved on the Board. The Firmware is transferred as Serial Data from
the SC PCB.
D. Panel (PNL) PC Board Firmware
The 4 MB Program Memory (F-ROM) is integrated on the PNL PCB. The Programs for Key Scan,
Display Control, Energy Save Control, Bitmap Data and Font Data are saved on this Board. The
Firmware is transferred as Serial Data from the SC PCB.
E. Firmware Updating Ports
Three (3) types of Ports are available for updating the firmware.
(1) Ethernet LAN Port (The Quickest and Most Easiest Method)
The machine's Firmware can be updated from a PC via Local Area Network (LAN). Refer to the
Firmware Update Operation Instructions, Service Notes (8.1. of the Service Manual) for additional
details.
(2) USB Port (Alternate)
The machine's Firmware can be updated from a PC via USB Port. The Master Firmware Card can
also be created from a PC using the USB Port. Refer to the Firmware Update Operation
Instructions, Service Notes (8.1. of the Service Manual) for additional details.
(3) Flash Memory Card (Alternate)
The machine's Firmware can be updated using the Master Firmware Card. The Master Firmware
Card can be created by copying the Firmware from an existing machine's SC PCB using a 4 MB or
8 MB Flash Memory Card.
To update the SC, SPC and PNL PCB, 3 Flash Memory Cards are required for the Standard
configuration or 5 Flash Memory Cards for the PCL or PS/PCL configuration.