Trouble Codes
Your controller is programmed to detect faults within its own system. If something happens to the controller system
that prevents your Jazzy from operating, you should see a trouble code. This is indicated by the System Status
Indicator flashing a number of times, then pausing for two seconds, then flashing again. Faults that affect the safety
of your Jazzy cause the chair to stop, while others allow the Jazzy to operate. Some trouble codes stop if the
condition corrects itself. Others can only be cleared by powering down the chair, then powering it up again.
Before you perform any of the electrical connection corrective actions listed in the following table, make sure that
you have fully charged batteries and you power down the system. In each case, if the corrective action does not
work, contact your service center.
Code
Title
1
DX Module Fault
2
DX Accessory Fault
3
Left Motor Fault
4
Right Motor Fault
5
Left Park Brake Fault
6
Right Park Brake Fault
7
Low Battery Fault
8
Overvoltage Fault
9
CANL Fault
10
CANH Fault
11
Stall Timeout Fault
12
Module Mismatch
40
V I I I .
O P E R A T I O N
Corrective Action
Turn the controller off, then on again. If this does not work, check the
connections at the joystick, the power module, and any other accessory module
that your Jazzy may have. If this still does not work, contact your local Pride
provider.
Power down the Jazzy and check all the connections to your accessories. You
may have a shorted circuit in one of these connections (e.g., a light bulb is
shorted or open).
Check the connection between the power module and the left motor. There may
be a short or bad connection. The motor itself may be bad.
Check the connection between the power module and the right motor. There
may be a short or bad connection. The motor itself may be bad.
Check the connection between the power module and the left motor. There may
be a short or bad connection.
Check the connection between the power module and the right motor. There
may be a short or bad connection.
Check the battery connections and terminals. Check that the circuit breaker is
not tripped. Reset it if necessary.
Contact your service center.
Contact your service center.
Contact your service center.
Turn the system off, then turn it on again.
Contact your service center.
www.pridemobility.com