Components (Generator) - MULTIQUIP GA6HB Operation And Parts Manual

(honda gx340r2edn2/gx340r2ede2 gasoline engines)
Hide thumbs Also See for GA6HB:
Table of Contents

Advertisement

120/240V
30A
1
12
1. 120/240v Output Receptacle – NEMA L14-30R twist-
lock receptacle will provide 240V, 60 Hz @ 20.8 amps,
or 120V@ 41.6 amps (X2) 60 Hz. Depending on the
position of the full power switch.
2. 120v Output Receptacle – NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
3. 120v Output Receptacle – NEMA L5-20R twist-lock
receptacle will provide 120V, 20 amps, 60 Hz.
4. lifting Ball Eye – Attach a rope or chain to this lifting
eye when lifting of the generator is required. Never
stand underneath the generator while it is being lifted.
Place lifting eye in down position when not in use.
5. gFCi sensing module – Interrupts power when a
ground fault exist.
6. main Breaker – This 2-pole, 23 amp circuit breaker
protects the generator from short circuiting or
overloading. When starting the generator always have
the circuit breaker placed in the "OFF" position.
7. AC-voltmeter – This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator OFF and consult your
authorized Multiquip service dealer.
ga6HB/6HeB 60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14) — pAgE 17
4
2
3
8
5
6
7
GA-6HB
V
120
120
F
P
O
A
W
U
E
L
AC VOLTMETER
IDLE
R
T
CONTROL
120V
120
120
MANUAL RESET
30A
20A
AC CIRCUIT BREAKER
120V/240V
120V
GFCI PROTECTED
FULL POWER
SWITCH
120 V
120 V
20A
20A
IN SIMULTANEOUS USE 30 AMP MAX
10
Figure 3. Generator Components

ComPonenTs (GeneRaToR)

9
ON
0N
OFF
OFF
OPERATION
SWITCH
120/240V
30A
11
8. idle Control switch – The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched "ON", the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
9. Operation switch – Place switch in the "ON" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "OFF" position (down).
10. gFCi duplex Receptacles – NEMA 5-20R, GFCI
receptacle will provide 120V@ 20 amps.
11. ground – This ground connection point should be
connect to a good earth ground (ground rod).
12. Charcoal Canister – A container filled with activated
charcoal that traps gasoline vapors emitted by the
fuel system.
13. start switch – Press this pushbutton switch to start
the generator (GA6HEB only).
14. Battery – This unit is equipped with a 12 VDC
battery. Replace with only recommended type battery
(GA6HEB only).
GA-6HEB
V
120
ELECTRIC START
120
F
P
O
A
W
U
E
L
AC VOLTMETER
IDLE
R
T
CONTROL
120V
120
120
13
MANUAL RESET
30A
20A
AC CIRCUIT BREAKER
120V/240V
120V
GFCI PROTECTED
FULL POWER
SWITCH
120 V
120 V
20A
20A
IN SIMULTANEOUS USE 30 AMP MAX
14
9
0N
OFF
OPERATION
SWITCH
START
SWITCH