Installation Of Remote Condenser Unit; Checks Before Installation; Location - Hoshizaki STACKABLE CRESCENT CUBER KM-1800SAH/3 Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for STACKABLE CRESCENT CUBER KM-1800SAH/3:
Table of Contents

Advertisement

G. Installation of Remote Condenser Unit

1. Checks Before Installation

1) Unpack and remove shipping carton, tape(s) and packing.
) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade turns freely.

2. Location

The condenser unit must be positioned in a permanent site under the following guidelines.
• A firm and flat site.
• A dry and well ventilated area with 4" clearance on both front and rear for ease of
maintenance and service should they be required.
• Normal condenser ambient temperature: -0°F to +1°F (-9°C to +50°C).
Temperatures not within this operating range may affect the production capacity of the
icemaker.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an
installation require a longer line length, please call 1-800-33-1940 for recommendations
concerning the correct additional refrigerant charge to be added.
Note: If the recommended guidelines of the installation are exceeded, the icemaker
performance may be reduced.
Air
Air
Fig. 9
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1800sahKm-1800srhKm-1800srh3Km-1800swhKm-1800swh3

Table of Contents